| Literature DB >> 27397450 |
Pushkar Mahendra Desai1, Sanjeeta R Umbarkar1, Manjula S Sarkar1, Rishi Lohiya2.
Abstract
OBJECTIVE: The aim of this study is to determine safety and feasibility of conscious sedation using dexmedetomidine for transcatheter atrial septal defect (ASD) device closure.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27397450 PMCID: PMC4971974 DOI: 10.4103/0971-9784.185528
Source DB: PubMed Journal: Ann Card Anaesth ISSN: 0971-9784
Figure 1(a) Amplatzer sheath crossing atrial septal defect. (b) Bicaval view showing undeployed Amplatzer device. (c) Three-dimensional transesophageal echocardiographic showing Amplatzer device across atrial septal defect
Demographic data
| Parameter | Mean±SD |
|---|---|
| Age range (years) | 12-56 |
| Mean age (years) | 31.56±13.74 |
| Sex | 36 females, 7 males |
| Weight (kg) | 46.86±14.34 |
| ASD size (mm) | 22.34±5.15 |
| Amplatzer device size (mm) | 27±4.87 |
ASD: Atrial septal defect, SD: Standard deviation
Recovery and miscellaneous data
| Parameter | Mean±SD |
|---|---|
| Anesthesia time (min) | 71.75±21.08 |
| Procedure time (min) | 61.02±23.84 |
| Recovery time (min) | 7.64±3.01 |
| Procedure success rate (%) | 93.02 |
| Hospital stay (days) | 1.48±0.51 |
| Patient Satisfaction (%) | 43/43 (100) |
Hemodynamic characteristics
| Parameter | Baseline | Post-TEE insertion | Post-TEE removal |
|---|---|---|---|
| HR (min) | 86.34±6.39 | 98.82±4.66 | 81.02±9.52 |
| MAP (mmHg) | 88.62±6.74 | 94.66±9.23 | 84.44±5.78 |
TEE: Transesophageal echocardiogram, HR: Heart rate, MAP: Mean arterial pressure
Peri-procedural complications
| Complication | Incidence |
|---|---|
| Hypotension/bradycardia | 0/43 |
| Nausea/vomiting | 0/43 |
| Atrial fibrillation | 4/43 |
| Procedure abandoned | 3/43 |