Literature DB >> 27396630

Percutaneous Closure of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation: A Systematic Review.

Tomo Ando1, Hisato Takagi2.   

Abstract

Paravalvular regurgitation (PVR) remains one of the drawbacks of transcatheter aortic valve implantation (TAVI). Details of percutaneous closure (PCC) of PVR after TAVI remain obscure. We aimed to explore the patient characteristics, procedural details, closure devices used, and outcomes of PCC after TAVI. A systematic search of the MEDLINE/PubMed and Embase databases from January 2002 to September 2015 was conducted. Reports considered to include same patient were excluded and only the studies with largest cohorts were included. A total of 14 studies including 58 patients (61 cases) were included in the study. A balloon-expandable (BE) valve was used more frequently compared with a self-expandable (SE) valve (72.6% vs 27.4%, respectively). The mean success rate was 86.9% (100% and 77.8%, respectively; P = 0.097). The median number of closure devices used was 1 (range, 1-4) and did not differ between SE and BE valves (P = 0.71). Mean time from index procedure to PCC did not differ between SE and BE valves (295 ± 380 days vs 379 ± 353 days; P = 0.71). Seven patients had history of valve-in-valve and 6 patients had procedural success. Among the patients with available follow-up data (94.8%), there were 15 deaths (27.3%). Percutaneous closure of PVR after TAVI had a high success rate in selected patients in both BE and SE valves. The success rate, timing, and number of closure devices were similar between BE and SE valves. However, prognosis remains fairly poor.
© 2016 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2016        PMID: 27396630      PMCID: PMC6490807          DOI: 10.1002/clc.22569

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  3 in total

Review 1.  Paravalvular Leak in Structural Heart Disease.

Authors:  Kashish Goel; Mackram F Eleid
Journal:  Curr Cardiol Rep       Date:  2018-03-06       Impact factor: 2.931

2.  Fluid-Structure Interaction Analysis on the Influence of the Aortic Valve Stent Leaflet Structure in Hemodynamics.

Authors:  Xiangkun Liu; Wen Zhang; Ping Ye; Qiyi Luo; Zhaohua Chang
Journal:  Front Physiol       Date:  2022-05-13       Impact factor: 4.755

3.  Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection.

Authors:  Róbert Novotný; Jaroslav Hlubocký; Tomáš Kovárník; Petr Mitáš; Zuzana Hlubocka; Jan Rulíšek; Sevim Ismihan Gulmez; Shubjiwan Kaur Ghotra; Jaroslav Lindner
Journal:  Case Rep Cardiol       Date:  2017-04-30