Literature DB >> 27395753

Comparison of corneal topographic measurements and high order aberrations in keratoconus and normal eyes.

Hatice Nur Colak1, Feride Aylin Kantarci2, Aydin Yildirim2, Mehmet Gurkan Tatar2, Hasan Goker2, Hasim Uslu2, Bulent Gurler2.   

Abstract

PURPOSE: The aim of this report was to compare corneal topographic measurements and anterior high order corneal aberrations in eyes with keratoconus and normal eyes by using Scheimpflug-Placido topography.
METHODS: Eighty cases diagnosed with mild (group 1), moderate (group 2), and advanced (group 3) stage keratoconus (KC) according to Amsler-Krumeich Classification and 81 healthy (control group) cases were retrospectively examined. The mean keratometric measurements (as both diopters (Kavg) and mm values (mmavg)), central corneal thickness values (CCT), high order aberration (HOA), total wavefront aberration (TWA), coma, trefoil, and spherical aberration measurements were performed using Sirius topography equipment. The topographic values were compared between the groups.
RESULTS: There were 25 cases in group 1 KC (15.5%), 34 cases in group 2 KC (21.1%), 21 cases in group 3 KC (13.1%), and 81 cases (50.3%) in the control group. In terms of mean age and gender distributions, there was no statistically significant difference between the groups (p>0.05). However, there was significant difference between the groups in terms of Kavg, CCT, HOA, TWA, coma, trefoil, and spherical aberration values (p<0.01). Mean HOA, TWA, coma, trefoil, and spherical aberration values were observed to increase with the severity of KC disease.
CONCLUSIONS: Anterior high order corneal aberrations were significantly increased in eyes with moderate and advanced keratoconus. Anterior high order corneal aberration measurements are a useful tool to guide the physician in diagnosis and classification of keratoconus.
Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aberrations; Corneal topography; Keratoconus

Mesh:

Year:  2016        PMID: 27395753     DOI: 10.1016/j.clae.2016.06.005

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  8 in total

1.  Distinguishing Highly Asymmetric Keratoconus Eyes Using Dual Scheimpflug/Placido Analysis.

Authors:  Oren Golan; Andre L Piccinini; Eric S Hwang; Ildamaris Montes De Oca Gonzalez; Mark Krauthammer; Sumitra S Khandelwal; David Smadja; J Bradley Randleman
Journal:  Am J Ophthalmol       Date:  2019-02-02       Impact factor: 5.258

2.  Best indices of dual Scheimpflug/Placido tomographer for keratoconus detection.

Authors:  Zahra Heidari; Ebrahim Jafarzadehpour; Mehrdad Mohammadpour; Hassan Hashemi
Journal:  Int Ophthalmol       Date:  2022-09-23       Impact factor: 2.029

3.  Diagnostic value of corneal higher-order aberrations in keratoconic eyes.

Authors:  Jing Li; Chao Xue; Yaohua Zhang; Zhiqing Wu; Chunlei Liu; Jing Du; Yong Li; Jianguo Liu; Shengsheng Wei
Journal:  Int Ophthalmol       Date:  2022-09-23       Impact factor: 2.029

4.  Aberrometry Repeatability and Agreement with Autorefraction.

Authors:  Mylan T Nguyen; David A Berntsen
Journal:  Optom Vis Sci       Date:  2017-09       Impact factor: 1.973

5.  A predictive model for early diagnosis of keratoconus.

Authors:  Gracia Castro-Luna; Antonio Pérez-Rueda
Journal:  BMC Ophthalmol       Date:  2020-07-02       Impact factor: 2.209

6.  A model of visual limitation in patients with keratoconus.

Authors:  Antonio Pérez-Rueda; Gracia Castro-Luna
Journal:  Sci Rep       Date:  2020-11-09       Impact factor: 4.379

7.  Comparison of Clinical and Topographic Outcomes of Hybrid and Scleral Lenses in Advanced Keratoconus.

Authors:  Betul Ilkay Sezgin Akcay; Alev Kockar; Utku Limon; Esra Kardes; Aslihan Dogan Dursun
Journal:  Beyoglu Eye J       Date:  2021-02-18

8.  Assessment of the Association between In Vivo Corneal Morphogeometrical Changes and Keratoconus Eyes with Severe Visual Limitation.

Authors:  J S Velázquez; F Cavas; J Alió Del Barrio; D G Fernández-Pacheco; J Alió
Journal:  J Ophthalmol       Date:  2019-09-22       Impact factor: 1.909

  8 in total