Evaluation of 2 portable ion-selective electrode meters for determining whole blood, plasma, urine, milk, and abomasal fluid potassium concentrations in dairy cattle.

A A Megahed1, M W H Hiew1, W Grünberg1, P D Constable2.   

Abstract

Two low-cost ion-selective electrode (ISE) handheld meters (CARDY C-131, LAQUAtwin B-731; Horiba Ltd., Albany, NY) have recently become available for measuring the potassium concentration ([K(+)]) in biological fluids. The primary objective of this study was to characterize the analytical performance of the ISE meters in measuring [K(+)] in bovine whole blood, plasma, urine, milk, and abomasal fluid. We completed 6 method comparison studies using 369 whole blood and plasma samples from 106 healthy periparturient Holstein-Friesian cows, 138 plasma samples from 27 periparturient Holstein-Friesian cows, 92 milk samples and 204 urine samples from 16 lactating Holstein-Friesian cows, and 94 abomasal fluid samples from 6 male Holstein-Friesian calves. Deming regression and Bland-Altman plots were used to characterize meter performance against reference methods (indirect ISE, Hitachi 911 and 917; inductively coupled plasma-optical emission spectroscopy). The CARDY ISE meter applied directly in plasma measured [K(+)] as being 7.3% lower than the indirect ISE reference method, consistent with the recommended adjustment of +7.5% when indirect ISE methods are used to analyze plasma. The LAQUAtwin ISE meter run in direct mode measured fat-free milk [K(+)] as being 3.6% lower than the indirect ISE reference method, consistent with a herd milk protein percentage of 3.4%. The LAQUAtwin ISE meter accurately measured abomasal fluid [K(+)] compared to the indirect ISE reference method. The LAQUAtwin ISE meter accurately measured urine [K(+)] compared to the indirect ISE reference method, but the median measured value for urine [K(+)] was 83% of the true value measured by inductively coupled plasma-optical emission spectroscopy. We conclude that the CARDY and LAQUAtwin ISE meters are practical, low-cost, rapid, accurate point-of-care instruments suitable for measuring [K(+)] in whole blood, plasma, milk, and abomasal fluid samples from cattle. Ion-selective electrode methodology is not suitable for measuring [K(+)] in bovine urine.
Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  hypokalemia; point-of-care

Mesh:

Substances:

Year:  2016        PMID: 27394952     DOI: 10.3168/jds.2015-10821

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  3 in total

1.  Comparative study on 3 oral potassium formulations for treatment of hypokalemia in dairy cows.

Authors:  Thomas Wittek; Anja Elvira Müller; Franz Wolf; Stephanie Schneider
Journal:  J Vet Intern Med       Date:  2019-05-17       Impact factor: 3.333

2.  Evaluation of hand-held sodium, potassium, calcium, and electrical conductivity meters for diagnosing subclinical mastitis and intramammary infection in dairy cattle.

Authors:  Sahar A Kandeel; Ameer A Megahed; Peter D Constable
Journal:  J Vet Intern Med       Date:  2019-07-11       Impact factor: 3.333

3.  Acute coumaphos organophosphate exposure in the domestic dogs: Its implication on haematology and liver functions.

Authors:  O E Ola-Davies; O I Azeez; A A Oyagbemi; M O Abatan
Journal:  Int J Vet Sci Med       Date:  2018-05-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.