Strain mapping and correlative microscopy of the alveolar bone in a bone-periodontal ligament-tooth fibrous joint.

Andrew Jang1, Richard Prevost2, Sunita P Ho1.   

Abstract

This study details a method to calculate strains within interradicular alveolar bone using digital volume correlation on X-ray tomograms of intact bone-periodontal ligament-tooth fibrous joints. The effects of loading schemes (concentric and eccentric) and optical magnification on the resulting strain in alveolar bone will be investigated with an intent to correlate deformation gradients with data sets from other complementary techniques. Strain maps will be correlated with structural and site-specific mechanical properties obtained on the same specimen using atomic force microscopy and atomic force microscopy-based nanoindentation technique. Specimens include polydimethylsiloxane as a standard material and intact hemi-mandibles harvested from rats. X-ray tomograms were taken at no-load and loaded conditions using an in situ load cell coupled to a micro X-ray computed tomography unit. Digital volume correlation was used to calculate deformations within alveolar bone. Comparison of strain maps was made as a result of different loading schemes (concentric vs eccentric) and at different magnifications (4× vs 10×). Virtual sections and strain maps from digital volume correlation solutions were aligned with structure and reduced elastic modulus to correlate datasets of the same region within a specimen. Strain distribution between concentrically and eccentrically loaded complexes was different but illustrated a similar range. Strain maps of homogeneous materials (polydimethylsiloxane) resulting from digital volume correlation at different magnifications were similar. However, strain maps of heterogeneous materials at lower and higher magnification differed. The digital volume correlation technique illustrated a dependence on optical magnification specifically for heterogeneous materials such as bone. The results at a higher optical magnification highlight the potential for extracting deformation at higher resolutions. Correlation of data spaces from different complementary techniques is plausible and could provide insights into biological and physicochemical processes that lead to functional adaptation of tissues and joints.

Entities:  

Keywords:  Digital volume correlation; X-ray microscopy; biomechanics; bone–periodontal ligament–tooth complex; correlative microscopy; fibrous joint

Year:  2016        PMID: 27381024     DOI: 10.1177/0954411916655183

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  2 in total

Review 1.  Periodontal ligament entheses and their adaptive role in the context of dentoalveolar joint function.

Authors:  Jeremy D Lin; Andrew T Jang; Michael P Kurylo; Jonathan Hurng; Feifei Yang; Lynn Yang; Arvin Pal; Ling Chen; Sunita P Ho
Journal:  Dent Mater       Date:  2017-05-02       Impact factor: 5.304

2.  Functional adaptation of interradicular alveolar bone to reduced chewing loads on dentoalveolar joints in rats.

Authors:  Andrew Jang; Bo Wang; Putu Ustriyana; Stuart A Gansky; Igor Maslenikov; Alex Useinov; Richard Prevost; Sunita P Ho
Journal:  Dent Mater       Date:  2021-02-12       Impact factor: 5.304