Literature DB >> 27376956

Damage mechanisms at the cement-implant interface of polished cemented femoral stems.

Natalie Shearwood-Porter1, Martin Browne1, James A Milton2, Matthew J Cooper2, Martin R Palmer2, Jeremy M Latham3, Robert J K Wood4, Richard B Cook4.   

Abstract

The occurrence of damage on polished femoral stems has been widely reported in the literature, and bone cement has been implicated in a tribocorrosive failure process. However, the mechanisms of cement-mediated damage and the impact of cement formulation on this process are not well understood. In this study, 13 Zimmer CPT polished femoral stems, and the corresponding cement specimens were retrieved at revision surgery and analyzed using high-resolution imaging techniques. Surface damage attributed to tribocorrosion was observed on all stems. Corrosion product, in the form of black flaky surface debris, was observed on the surface of cement specimens; both energy-dispersive X-ray spectroscopy and inductively coupled plasma mass spectrometry(ICP-MS) confirmed the presence of cobalt and chromium, with the ICP-MS showing much higher levels of Cr compared to Co when compared to the original stem material. Agglomerates of ZrO2 radiopacifier were also identified on the cement surface and, in some cases, showed evidence of abrasive wear; the size of these particles correlated well with elliptical pitting evident on the surfaces of the corresponding stems. This evidence supports the hypothesis that agglomerates of hard radiopacifier particles within the cement may induce a wear-dominated tribocorrosive interaction at the stem-cement interface that damages the surface of polished CoCr femoral stems.
© 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2027-2033, 2017. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  bone cement; cobalt-chromium alloys; corrosion; failure analysis; implant retrieval

Mesh:

Substances:

Year:  2016        PMID: 27376956     DOI: 10.1002/jbm.b.33739

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  2 in total

1.  Corrosion of Polished Cobalt-Chrome Stems Presenting as Cobalt Encephalopathy.

Authors:  Stephen S Tower; Dana J Medlin; Robert L Bridges; Christina S Cho
Journal:  Arthroplast Today       Date:  2020-12-02

2.  Use of Deep Learning Networks and Statistical Modeling to Predict Changes in Mechanical Parameters of Contaminated Bone Cements.

Authors:  Anna Machrowska; Jakub Szabelski; Robert Karpiński; Przemysław Krakowski; Józef Jonak; Kamil Jonak
Journal:  Materials (Basel)       Date:  2020-11-28       Impact factor: 3.623

  2 in total