Literature DB >> 27375321

Evaluation of Vitreous Substitutes in Managing Complicated Vitreo-retinal Surgeries.

V S Gurunadh1, A Banarji2, S Patyal1, A K Upadhyay3, T S Ahluwalia4, R P Gupta5, M Bhaduria6.   

Abstract

BACKGROUND: Vitreous substitutes presently in use for intraoperative tamponade are perfluorocarbon liquids (PFCL) and for post operative tamponade are silicon oil (SO), sulphur hexafluoride (SF6) and perfluorocarbon gas (PFC). Several factors are important for a thorough understanding of each of these vitreous substitutes. The absorption or necessity for removal, indications for use (including clinical studies and special surgical methods), additives and complications of use have to be considered.
METHODS: Three port standard pars plana vitrectomy was performed in 60 consecutive cases requiring intra-vitreal intervention. PFCL was used intra-operatively in 30 cases (PFCL group and X group). The eyes were implanted with SO (silicon oil subgroup), PFC (C3F8 sub-group) and SF6 (SF6 sub-group) in twenty cases each. Apart from best corrected visual acuity (BCVA), the retinal status and the longevity of gas when used, changes and reaction in both the anterior and posterior segments were noted. RESULT: The difference of postoperative BCVA in the PFCL and non-PFCL groups was statistically significant with p < 0.001. In both the PFCL and non-PFCL groups the difference between preoperative and postoperative BCVA was statistically significant with p < 0.0001. All three vitreous substitutes studied are effective given the case where they had been utilised.
CONCLUSION: PFCL is invaluable in the management of complicated retinal detachment (RD). Where a vitreous microsurgery is indicated, the visual outcome is good. SF6 is useful for short-term tamponade. Silicon oil and C3F8 are useful for longer tamponade.

Entities:  

Keywords:  Perfluorocarbon gas; Perfluorocarbon liquids; Retinal detachment; Silicon oil; Sulphur hexafluoride; Tamponade

Year:  2011        PMID: 27375321      PMCID: PMC4920919          DOI: 10.1016/S0377-1237(10)80123-6

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  5 in total

1.  25-gauge vitrectomy using sulfur hexafluoride and no prone positioning for repair of macular holes.

Authors:  Petros E Carvounis; Andrew C Kopel; Derek P Kuhl; Jordan Heffez; Kathryn Pepple; Eric R Holz
Journal:  Retina       Date:  2008-10       Impact factor: 4.256

2.  Vitreous Substitutes.

Authors:  William Joseph Foster
Journal:  Expert Rev Ophthalmol       Date:  2008-04

3.  Outcomes of sulfur hexafluoride (SF6) versus perfluoropropane (C3F8) gas tamponade for macular hole surgery.

Authors:  Sung Soo Kim; William E Smiddy; William J Feuer; Wei Shi
Journal:  Retina       Date:  2008 Nov-Dec       Impact factor: 4.256

4.  Outcome of pneumatic retinopexy at a tertiary eye care centre in Nepal.

Authors:  R Thapa; M K Shrestha; R Gurung; S Ruit; G Paudyal
Journal:  Kathmandu Univ Med J (KUMJ)       Date:  2008 Oct-Dec

5.  Prognostic factors after primary vitrectomy and perfluorocarbon liquids for bullous rhegmatogenous retinal detachment.

Authors:  A M Abu El-Asrar; H F Al-Kwikbi; D Kangave
Journal:  Eur J Ophthalmol       Date:  2009 Jan-Feb       Impact factor: 2.597

  5 in total