Literature DB >> 27375069

Photopic and Mesopic Performance of 2 Different Trifocal Diffractive Intraocular Lenses.

Jose M Martinez-de-la-Casa1,2,3, Jesús Carballo-Alvarez4, Javier Garcia-Bella1,2,3, Jose M Vazquez-Molini4, Laura Morales1,2,3, Juan C Sanz-Fernandez4, Vicente Polo5, Julián García-Feijoo1,2,3.   

Abstract

Purpose To assess photopic and mesopic vision in patients implanted with 2 different trifocal intraocular lenses (IOLs). Methods Fifty patients with cataract in both eyes had surgery with bilateral implantation of a trifocal FineVision (FV, n = 25) or AT LISA tri 839MP (LisaTri, n = 25) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were determined using the Early Treatment Diabetic Retinopathy Study test. Intermediate (65 cm) and near (40 cm) visual acuity were also measured, both with best distance correction (DCIVA and DCNVA, respectively). The CSV1000 test chart was used for binocular and monocular contrast sensitivity. Defocus curves were constructed under photopic and mesopic conditions. Results Mean patient age was 68.4 ± 5.5 years (FV) and 67.3 ± 5.6 years (LisaTri) (p = 0.540). No differences were found in terms of visual acuity between the groups. The CDVA, DCIVA, and DCNVA were 0.05 ± 0.06, 0.25 ± 0.10, and 0.13 ± 0.10 logMAR for FV and -0.04 ± 0.11, 0.32 ± 0.09, and 0.12 ± 0.11 logMAR for LisaTri, respectively (p = 0.09, p = 0.08, and p = 0.12). Photopic and mesopic defocus curves were comparable between the 2 IOL groups (p>0.05). Mesopic values were significantly worse than photopic in both groups for all the measured values (p<0.001). No differences in contrast sensitivity were observed between the 2 IOL groups (p>0.05). Conclusions Both trifocal diffractive IOLs provided good visual quality with a statistically significant decrease in mesopic conditions.

Entities:  

Keywords:  Cataract; Defocus; Intraocular lens; Mesopic; Photopic; Trifocal

Year:  2017        PMID: 27375069     DOI: 10.5301/ejo.5000814

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  3 in total

1.  Comparative analysis of visual outcomes, reading skills, contrast sensitivity, and patient satisfaction with two models of trifocal diffractive intraocular lenses and an extended range of vision intraocular lens.

Authors:  Rita Mencucci; Eleonora Favuzza; Orsola Caporossi; Alfonso Savastano; Stanislao Rizzo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-06       Impact factor: 3.117

Review 2.  AcrySof IQ PanOptix Intraocular Lens Versus Extended Depth of Focus Intraocular Lens and Trifocal Intraocular Lens: A Clinical Overview.

Authors:  Rachapalle Reddi Sudhir; Arindam Dey; Shovan Bhattacharrya; Amit Bahulayan
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019 Jul-Aug

3.  Short term visual outcomes of a new trifocal intraocular lens.

Authors:  Jorge L García-Pérez; Juan Gros-Otero; Celia Sánchez-Ramos; Vanesa Blázquez; Inés Contreras
Journal:  BMC Ophthalmol       Date:  2017-05-17       Impact factor: 2.209

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.