Literature DB >> 27373373

Zeolite/iron oxide composite as sorbent for magnetic solid-phase extraction of benzene, toluene, ethylbenzene and xylenes from water samples prior to gas chromatography⬜mass spectrometry.

Elena Fernández1, Lorena Vidal2, Antonio Canals3.   

Abstract

This study reports a new composite based on ZSM-5 zeolite decorated with iron oxide magnetic nanoparticles as a valuable sorbent for magnetic solid-phase extraction (MSPE). A proposal is made to determine benzene, toluene, ethylbenzene and xylenes (BTEX) as model analytes in water samples using gas chromatography-mass spectrometry. A two-step multivariate optimization strategy, using Plackett⬜Burman and circumscribed central composite designs, was employed to optimize experimental parameters affecting MSPE. The method was evaluated under optimized extraction conditions (i.e., amount of sorbent, 138mg; extraction time, 11min; sample pH, pH of water (i.e., 5.5⬜6.5); eluent solvent volume, 0.5mL; and elution time, 5min), obtaining a linear response from 1 to 100μgL(↙1) for benzene; from 10 to 100μgL(↙1) for toluene, ethylbenzene and o-xylene; and from 10 to 75μgL(↙1) for m,p-xylene. The repeatability of the proposed method was evaluated at a 40μgL(↙1) spiking level and coefficients of variation ranged between 8 and 11% (n=5). Limits of detection were found to be 0.3μgL(↙1) for benzene and 3μgL(↙1) for the other analytes. These values satisfy the current normative of the Environmental Protection Agency and European Union for BTEX content in waters for human consumption. Finally, drinking water, wastewater and river water were selected as real water samples to assess the applicability of the method. Relative recoveries varied between 85% and 114% showing negligible matrix effects.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  BTEX; Gas chromatography-mass spectrometry; Magnetic solid-phase extraction; Water samples; ZSM-5 zeolite

Mesh:

Substances:

Year:  2016        PMID: 27373373     DOI: 10.1016/j.chroma.2016.06.049

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Magnetic dispersive solid-phase extraction using a zeolite-based composite for direct electrochemical determination of lead(II) in urine using screen-printed electrodes.

Authors:  Elena Fernández; Lorena Vidal; Joaquín Silvestre-Albero; Antonio Canals
Journal:  Mikrochim Acta       Date:  2020-01-02       Impact factor: 5.833

2.  Graphene and zeolite as adsorbents in bar-micro-solid phase extraction of pharmaceutical compounds of diverse polarities.

Authors:  Maizatul Najwa Jajuli; Grégoire Herzog; Marc Hébrant; Ng Eng Poh; Afidah Abdul Rahim; Bahruddin Saad; M Hazwan Hussin
Journal:  RSC Adv       Date:  2021-05-04       Impact factor: 4.036

3.  Ultra-fast responsive colloidal-polymer composite-based volatile organic compounds (VOC) sensor using nanoscale easy tear process.

Authors:  Hyung-Kwan Chang; Gyu Tae Chang; Ashish K Thokchom; Taesung Kim; Jungyul Park
Journal:  Sci Rep       Date:  2018-03-28       Impact factor: 4.379

Review 4.  Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications.

Authors:  Syahidah Nurani Zulkifli; Herlina Abdul Rahim; Woei-Jye Lau
Journal:  Sens Actuators B Chem       Date:  2017-09-18       Impact factor: 7.460

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.