OBJECTIVES: The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. SYSTEMATIC REVIEW
METHODOLOGY: Relevant publications on plateau iris that were published until 2014.
CONCLUSIONS: Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 27373109      PMCID: PMC5729809     

Source DB:  PubMed          Journal:  Rom J Ophthalmol        ISSN: 2457-4325


  14 in total

Review 1.  Possible mechanisms of primary angle-closure and malignant glaucoma.

Authors:  Harry A Quigley; David S Friedman; Nathan G Congdon
Journal:  J Glaucoma       Date:  2003-04       Impact factor: 2.503

2.  Plateau iris syndrome.

Authors:  M Wand; W M Grant; R J Simmons; B T Hutchinson
Journal:  Trans Sect Ophthalmol Am Acad Ophthalmol Otolaryngol       Date:  1977 Jan-Feb

Review 3.  Mechanisms and treatment of primary angle closure: a review.

Authors:  Weng T Ng; William Morgan
Journal:  Clin Exp Ophthalmol       Date:  2011-07-26       Impact factor: 4.207

4.  [Argon laser iridoplasty in the treatment of angle closure glaucoma with plateau iris syndrome].

Authors:  B Tnacheri Ouazzani; M Berkani; M Ecoffet; Y Lachkar
Journal:  J Fr Ophtalmol       Date:  2006-06       Impact factor: 0.818

5.  [Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of plateau iris].

Authors:  C Parc; J Laloum; O Bergès
Journal:  J Fr Ophtalmol       Date:  2010-02-24       Impact factor: 0.818

6.  Optical coherence tomography in anterior segment imaging.

Authors:  Maya Kalev-Landoy; Alexander C Day; M Francesca Cordeiro; Clive Migdal
Journal:  Acta Ophthalmol Scand       Date:  2007-03-13

Review 7.  Argon laser peripheral iridoplasty (ALPI): an update.

Authors:  Robert Ritch; Clement C Y Tham; Dennis S C Lam
Journal:  Surv Ophthalmol       Date:  2007 May-Jun       Impact factor: 6.048

8.  Prevalence of plateau iris syndrome in young patients with recurrent angle closure.

Authors:  Roland Stieger; Christoph Kniestedt; Florian Sutter; Lucas M Bachmann; Joerg Stuermer
Journal:  Clin Exp Ophthalmol       Date:  2007-07       Impact factor: 4.207

9.  Prevalence of plateau iris configuration in primary angle closure glaucoma using ultrasound biomicroscopy in the Indian population.

Authors:  Gaurav Kumar; Shveta Jindal Bali; Anita Panda; Amit Sobti; Tanuj Dada
Journal:  Indian J Ophthalmol       Date:  2012 May-Jun       Impact factor: 1.848

10.  Peripheral laser iridoplasty opens angle in plateau iris by thinning the cross-sectional tissues.

Authors:  Ji Liu; Tania Lamba; David A Belyea
Journal:  Clin Ophthalmol       Date:  2013-09-23
View more
  7 in total

1.  Plateau iris syndrome and angle-closure glaucoma in a patient with nail-patella syndrome.

Authors:  Margot A Gardin; Chiea Chuen Khor; Luis Silva; Einar A Krefting; Robert Ritch
Journal:  Am J Ophthalmol Case Rep       Date:  2020-08-20

2.  Prevalence of Plateau Iris Syndrome among Patients Presenting with Primary Angle Closure and Primary Angle-Closure Glaucoma in a Tertiary Eye Care Hospital.

Authors:  Khalid Alshomar; Ehab Alsirhy; Abdullah Mirza; Mohamed Osman; Abdullah Alobaidan; Essam A Osman
Journal:  Middle East Afr J Ophthalmol       Date:  2022-04-30

3.  Repeatability and Reliability of Quantified Ultrasound Biomicroscopy Image Analysis of the Ciliary Body at the Pars Plicata.

Authors:  Joy Li; Jennifer Drechsler; Anna Lin; Matthew Widlus; Azam Qureshi; Gianna Stoleru; Osamah Saeedi; M Roni Levin; Mona Kaleem; Mohamad Jaafar; William P Madigan; Janet Leath Alexander
Journal:  Ultrasound Med Biol       Date:  2021-04-13       Impact factor: 3.694

4.  Long-Term Effect of Early Phacoemulsification in Primary Angle Closure Glaucoma Patients with Cataract: A 10-Year Follow-Up Study.

Authors:  Hazem Helmy
Journal:  Clin Ophthalmol       Date:  2021-09-29

5.  Prevalence of Plateau Iris in Primary Angle Closure Glaucoma: An Egyptian Hospital Based Ultrasound Biomicroscopy Study.

Authors:  Amira E Hamad; Ahmed F Elmaria; Tarek R Hussein; Said M Shalaby
Journal:  Clin Ophthalmol       Date:  2022-02-25

6.  Angle Closure with Patent Laser Peripheral Iridotomy - An Unusual Complication.

Authors:  Saswati Sen; Matuli Das; Tej Mehar Singh Chugh
Journal:  Int J Appl Basic Med Res       Date:  2021-11-17

Review 7.  Ultrasound biomicroscopy in glaucoma assessment.

Authors:  Vasile Potop; Valeria Coviltir; Speranţa Schmitzer; Christiana Diana Maria Dragosloveanu; Cătălina Ioana Ionescu; Miruna Gabriela Burcel; Maria Cristina Corbu; Dana Margareta Cornelia Dăscălescu
Journal:  Rom J Ophthalmol       Date:  2021 Apr-Jun
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.