Changes of the optical characteristics of radiochromic films in the transition from EBT3 to EBT-XD films.

Andreas A Schoenfeld1, Soeren Wieker, Dietrich Harder, Bjoern Poppe.   

Abstract

A new type of radiochromic film, the EBT-XD film, has been introduced with the aim to reduce the orientation effect and the lateral response artifact occurring in the use of radiochromic films together with flatbed scanners. The task of the present study is to quantify the changes of optical characteristics involved with the transition from the well-known EBT3 films to the new EBT-XD films, using the optical bench arrangement already applied by Schoenfeld et al (2014 Phys. Med. Biol. 59 3575-97). Largely reduced polarization effects and the almost complete loss of the anisotropy of the scattered light produced in a radiation-exposed film have been observed. The Rayleigh-Debye-Gans theory is used to understand these optical changes as arising from the reduced length-to-width ratio of the LiPCDA polymer crystals in the active layer of the EBT-XD film. The effect of these changes on the flatbed scanning artifacts will be shortly addressed, but treated in more detail in a further paper.

Entities:  

Year:  2016        PMID: 27367839     DOI: 10.1088/0031-9155/61/14/5426

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Correction of lateral response artifacts from flatbed scanners for dual-channel radiochromic film dosimetry.

Authors:  Yuichi Akino; Hiroya Shiomi; Fumiaki Isohashi; Osamu Suzuki; Yuji Seo; Keisuke Tamari; Takero Hirata; Hirokazu Mizuno; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2021-03-10       Impact factor: 2.724

2.  Alkali Metal Salts of 10,12-Pentacosadiynoic Acid and Their Dosimetry Applications.

Authors:  Amy V Hall; Osama M Musa; David K Hood; David C Apperley; Dmitry S Yufit; Jonathan W Steed
Journal:  Cryst Growth Des       Date:  2021-03-25       Impact factor: 4.076

3.  Monte Carlo calculation of the mass stopping power of EBT3 and EBT-XD films for protons for energy ranges of 50-400 MeV.

Authors:  Chengyu Shi; Chin-Cheng Chen; Dennis Mah; Maria F Chan
Journal:  Precis Radiat Oncol       Date:  2018-11-19

4.  Effect of scanner lens on lateral response artefact in radiochromic film dosimetry.

Authors:  Tarafder Shameem; Nick Bennie; Martin Butson; David Thwaites
Journal:  Phys Eng Sci Med       Date:  2022-05-30