Literature DB >> 27367204

The Varus Osteoarthritic Knee Has No Coronal Contractures in 90 Degrees of Flexion.

Michael J McAuliffe1, John Roe1, Gautam Garg1, Sarah L Whitehouse2, Ross Crawford2.   

Abstract

Medial and lateral coronal soft tissue laxity in 90 degrees of flexion in the varus osteoarthritic (OA) knee at the time of total knee arthroplasty (TKA) is unknown, meaning, key information as to how the flexion gap should be addressed by surgery is not available. The purpose of this study was to define the coronal plane medial and lateral laxity in 90 degrees of flexion in the end-stage OA knee. Computer assisted surgery (CAS) displays and direct joint observations were used to manipulate the knee to its neutral position in 90 degrees of flexion prior to any surgical releases. Laxity was measured as medial and lateral displacement from the neutral axis of the knee and compared with literature values for healthy subjects. The 72 knees examined had a mean varus deformity, measured in maximum extension, of -7.9 ± 3.1 degrees (-0.5 to -15 degrees). At 90 degrees of flexion, mean medial and lateral laxity as measured by displacement from the neutral axis of the knee was 3.8 ± 1.4 degrees and 4.7 ± 2 degrees respectively. This medial laxity was significantly greater -1.7 degrees (95% CI, -3.1 to -0.3 degrees) than that seen in healthy knees (p < 0.0001) whereas the measured lateral laxity displayed a nonsignificant difference compared with healthy knees. The mean difference in medial-lateral laxity was 1.5 ± 1.1 degrees. A medial-lateral difference of ≤2.5 degrees was present in 91.6% of knees. We found no evidence of contractures in the coronal plane tissue of the end-stage OA knee at the time of TKA. Absolute medial-lateral balance is not typical of the end-stage OA knee in 90 degrees of flexion with a small medial-lateral difference typically present. Careful examination of the soft tissues in flexion at the commencement of TKA may help guide surgery to optimize the coronal plane soft tissue envelope. Our findings would suggest that large releases during either a gap-balanced or a measured-resection TKA would not typically be necessary, and that releases that increase laxity in flexion may increase often already lax medial tissue or increase laxity within lateral tissues that typically already have physiological tension. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2016        PMID: 27367204     DOI: 10.1055/s-0036-1584539

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  5 in total

1.  Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances.

Authors:  William Blakeney; Yann Beaulieu; Benjamin Puliero; Marc-Olivier Kiss; Pascal-André Vendittoli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-14       Impact factor: 4.342

2.  Functional knee phenotypes of OA patients undergoing total knee arthroplasty are significantly more varus or valgus than in a non-OA control group.

Authors:  Jean-Yves Jenny; Florent Baldairon; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-08-11       Impact factor: 4.114

3.  The coronal alignment technique impacts deviation from native knee anatomy after total knee arthroplasty.

Authors:  Jean-Yves Jenny; Florent Baldairon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-09-20       Impact factor: 4.114

4.  Dynamic gap analysis of valgus knees shows large inter-individual variability of gaps.

Authors:  Kim Eller; Wolfgang Scior; Heiko Graichen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-09-09       Impact factor: 4.114

5.  Less gap imbalance with restricted kinematic alignment than with mechanically aligned total knee arthroplasty: simulations on 3-D bone models created from CT-scans.

Authors:  William Blakeney; Yann Beaulieu; Marc-Olivier Kiss; Charles Rivière; Pascal-André Vendittoli
Journal:  Acta Orthop       Date:  2019-10-15       Impact factor: 3.717

  5 in total