Literature DB >> 27367053

Short-Acting Gas Tamponade with Strict Face-Down Posturing for the Treatment of Idiopathic Macular Hole.

Stratos Gotzaridis1, Efstathios Liazos1, Petros Petrou2, Ilias Georgalas2.   

Abstract

PURPOSE: A retrospective consecutive case series to evaluate the safety and efficacy of 25 gauge pars plana vitrectomy, ILM peeling, 20% SF6 gas tamponade and strict posturing for the treatment of idiopathic full-thickness macular holes.
METHODS: We report the results of 106 consecutive eyes that underwent standard 25-gauge pars plana vitrectomy, brilliant peel-assisted internal limiting membrane peel, fluid:gas exchange with 20% SF6 and strict posturing for one week. All patients were followed up at one week, one month, three months, and nine months postoperatively. Biomicroscopy at day 1 and biomicroscopy and OCT at week 1, months 1, 3, and 9 were used to assess macular hole status postoperatively. Pre- and postoperative logMAR visual acuity was compared.
RESULTS: The macular hole was closed in 102/106 eyes postoperatively (96.2%). Four eyes showed unclosed macular holes and underwent additional SF6 intravitreal injection and strict posturing for 10 days. All macular holes were eventually closed without the need of a second surgical procedure. Mean visual acuity improved from 0.63 logMAR preoperatively to 0.39 logMAR postoperatively. One case of retinal toxicity was reported due to accidental intravitreal injection of antibiotic.
CONCLUSIONS: 25-gauge vitrectomy, ILM peel, and short-acting gas tamponade are highly effective for the treatment of macular holes. Additional intravitreal gas injection followed by strict posturing seems to be a simple and effective treatment for unclosed holes.

Entities:  

Keywords:  Internal limited membrane; intravitreal gas tamponade; macular hole; pars plana vitrectomy; short-acting gas

Mesh:

Substances:

Year:  2016        PMID: 27367053     DOI: 10.3109/08820538.2015.1132333

Source DB:  PubMed          Journal:  Semin Ophthalmol        ISSN: 0882-0538            Impact factor:   1.975


  2 in total

1.  Adherence to the face-down positioning after vitrectomy and gas tamponade: a time series analysis.

Authors:  Keita Suzuki; Yoshiaki Shimada; Yui Seno; Tadashi Mizuguchi; Atsuhiro Tanikawa; Masayuki Horiguchi
Journal:  BMC Res Notes       Date:  2018-02-20

2.  Outcomes of Light Silicone Oil Tamponade for Failed Idiopathic Macular Hole Surgery.

Authors:  M Hossein Nowroozzadeh; Hossein Ashraf; Mehdi Zadmehr; Mohsen Farvardin
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.