Literature DB >> 27365744

Comparative Evaluation of Two Techniques in Achieving Balanced Occlusion in Complete Dentures.

M Kumar1, Dsj D'Souza2.   

Abstract

BACKGROUND: This study was undertaken to evaluate new technique, which claims to reduce treatment time while retaining the quality of treatment. The aim of this study was to compare complete dentures made by two techniques: with the use of face bow and without the use of face bow.
METHODS: Twenty edentulous subjects were selected and each one received two pairs of complete dentures. Dentures were made from duplicated casts and each one followed different techniques. One technique used face-bow. Teeth were set using individualized wax rims as guides. In other technique an articulator was used, which avoids face-bow and teeth were set by the cast-analysis method. The number of occlusal contacts in centric relation and excursive movements were registered, in addition to this the opinion of patients regarding denture bearing during oral functions were taken. RESULT: Both groups had dentures with balanced occlusion, but the technique that avoids face-bow presented better results in regard to time taken, esthetics, comfort and stability. Balanced occlusion was provided even without face-bow and could be an alternative to obtain adequate complete dentures with a better prognosis.
CONCLUSION: For achieving better quality of denture in the form of esthetics, phonetics and function in short duration of time; a new technique was used to establish balanced occlusion in complete denture prostheses.

Entities:  

Keywords:  Articulators; Complete dentures; Occlusion

Year:  2011        PMID: 27365744      PMCID: PMC4919808          DOI: 10.1016/S0377-1237(10)80019-X

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  2 in total

Review 1.  Complete denture occlusion.

Authors:  B R Lang
Journal:  Dent Clin North Am       Date:  1996-01

Review 2.  Philosophy of occlusion: past and present.

Authors:  M M Ash
Journal:  Dent Clin North Am       Date:  1995-04
  2 in total
  5 in total

Review 1.  Biomechanical factors related to occlusal load transfer in removable complete dentures.

Authors:  Jarosław Żmudzki; Grzegorz Chladek; Jacek Kasperski
Journal:  Biomech Model Mechanobiol       Date:  2014-12-20

2.  The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study.

Authors:  Pokpong Amornvit; Sasiwimol Sanohkan
Journal:  Int J Environ Res Public Health       Date:  2019-12-12       Impact factor: 3.390

Review 3.  Utility versus futility of facebow in the fabrication of complete dentures: A systematic review.

Authors:  Poonam Prakash; Kirandeep Singh; Rahul Bahri; S K Bhandari
Journal:  J Indian Prosthodont Soc       Date:  2020-07-17

4.  Use of Facebow device in prosthodontics: A systematic review on randomized control trials.

Authors:  Vijyanta Suman; Nithin Kumar Sonnahalli; Ramesh Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2021 Jan-Mar

5.  Achieving Lingualized Balanced Occlusion in a Fixed-Removable Rehabilitation for a Maxillary Complete and Mandibular Kennedy Class II Case.

Authors:  Ibrahim Tulunoglu; Samuel Cohen
Journal:  Case Rep Dent       Date:  2019-10-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.