Literature DB >> 27364146

Intraoperative fluoroscopic assessment of proper prosthetic radial head height.

H Mike Kim1, Evan P Roush2, Casey Kiser2.   

Abstract

BACKGROUND: Selecting a properly sized radial head prosthesis is imperative during radial head replacement. Although there has been much emphasis on avoiding overlengthening of the radius, little has been studied about how to avoid shortening. The purpose of this study was to characterize how a radial head replacement appears on intraoperative fluoroscopy depending on the height of the prosthetic radial head.
METHODS: Articular cartilage thickness of the radial head was measured in 9 cadaveric elbows. Radial head replacement was performed in each specimen with 4 different prosthetic head heights: 4 mm and 2 mm shortening, anatomic, and 2 mm overlengthening. Anteroposterior fluoroscopic images were obtained for each head height, and the prosthetic radial head height was measured at 3 forearm positions (supination, neutral, and pronation) using the subchondral bone of the lateral edge of the coronoid at the reference point.
RESULTS: The mean cartilage thickness of the radial head was 1.3 ± 0.4 mm. The prosthetic radial head appeared 2.2 ± 0.4 mm more proximal than the subchondral bone of the coronoid lateral edge in anteroposterior radiographs when the articular surface of the prosthesis was completely even with the coronoid articular surface. Unlike the native radial head, a prosthetic radial head showed a significant change of height with different forearm rotation (P < .001). DISCUSSION: This study found that a perfectly anatomic radial head replacement appears overlengthened by approximately 2 mm in intraoperative radiographs. This finding can be useful in guiding the appropriate height of a prosthetic radial head.
Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Intraoperative fluoroscopy of prosthetic radial head; joint mechanics; prosthetic radial head; radial head fracture; radial head height; radial head replacement

Mesh:

Year:  2016        PMID: 27364146     DOI: 10.1016/j.jse.2016.04.014

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  4 in total

1.  [Radial head arthropolasty in unreconstructable comminuted fractures of the radial head: Long-term results and factors influencing the outcome].

Authors:  Ulf-Wilhelm Bökeler; Felix Kraft; Robert Schappacher; Verena Weisenberger; Anna Herlan; Ulrich C Liener
Journal:  Unfallchirurg       Date:  2022-01-25       Impact factor: 1.000

2.  Fracture Pattern Influences Radial Head Replacement Size Determination Among Experienced Elbow Surgeons.

Authors:  Davide Cucchi; Francesco Luceri; Andrea Celli; Alessandra Menon; Raul Barco; Kilian Wegmann; Pietro Randelli; Denise Eygendaal; Paolo Arrigoni
Journal:  Indian J Orthop       Date:  2020-03-18       Impact factor: 1.251

3.  Interobserver reliability of radiographic assessment after radial head arthroplasty.

Authors:  Rens Bexkens; Femke M A P Claessen; Izaäk F Kodde; Luke S Oh; Denise Eygendaal; Michel P J van den Bekerom
Journal:  Shoulder Elbow       Date:  2017-07-10

4.  Fluoroscopy of the Elbow: A Cadaveric Study Defining New Standard Projections to Visualize Important Anatomical Landmarks.

Authors:  Sebastian A Müller; Lars Adolfsson; Cornelia Baum; Magdalena Müller-Gerbl; Andreas M Müller; Daniel Rikli
Journal:  JB JS Open Access       Date:  2021-05-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.