Literature DB >> 27363298

Utility of Intravascular US-Guided Portal Vein Access during Transjugular Intrahepatic Portosystemic Shunt Creation: Retrospective Comparison with Conventional Technique in 109 Patients.

Anil K Pillai1, Brice Andring2, Nicholas Faulconer2, Stephen P Reis2, Yin Xi2, Ikponmwosa Iyamu3, Patrick D Suthpin2, Sanjeeva P Kalva2.   

Abstract

PURPOSE: To compare safety and effectiveness of intravascular ultrasound (US)-guided portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) creation with conventional TIPS technique.
MATERIALS AND METHODS: In this retrospective study, TIPS creation using intravascular US guidance in 55 patients was compared with conventional TIPS creation in 54 patients by 10 operators over a 3-year period. Operators were classified as experienced if they had performed ≥ 20 TIPS procedures at the beginning of the study period. Time to portal vein access, total radiation dose, and needle pass-related capsular perforation were recorded.
RESULTS: Baseline demographic characteristics of patients were similar (P > .05). Mean time to portal venous access was 46 minutes ± 37 for conventional TIPS and 31 minutes ± 19 for intravascular US-guided TIPS (P = .007). Intravascular US guidance allowed significantly shorter times (48 min ± 30 vs 28 min ± 16; P = .01) to portal vein access among operators (n = 5) with limited experience but failed to achieve any significant time savings (44 min ± 43 vs 34 min ± 22; P = .89) among experienced operators (n = 5). Needle pass-related capsular perforation occurred in 17/54 (34%) patients with conventional TIPS and 5/55 (9%) patients with intravascular US-guided TIPS (P = .004). Radiation dose was 2,376 mGy ± 1,816 for conventional TIPS and 1,592 mGy ± 1,263 for intravascular US-guided TIPS (P = .004).
CONCLUSIONS: Intravascular US-guided portal vein access during TIPS creation is associated with shorter portal vein access times, decreased needle pass-related capsular perforations, and reduced radiation dose.
Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27363298     DOI: 10.1016/j.jvir.2016.05.010

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  8 in total

Review 1.  New Techniques and Devices in Transjugular Intrahepatic Portosystemic Shunt Placement.

Authors:  Jamie RiChard; Bartley Thornburg
Journal:  Semin Intervent Radiol       Date:  2018-08-06       Impact factor: 1.513

2.  Fluoroless intravascular ultrasound image-guided liver navigation in porcine models.

Authors:  Takeshi Urade; Juan Manuel Verde; Alain García Vázquez; Konstanze Gunzert; Patrick Pessaux; Jacques Marescaux; Mariano Eduardo Giménez
Journal:  BMC Gastroenterol       Date:  2021-01-09       Impact factor: 3.067

Review 3.  Indian College of Radiology and Imaging Evidence-Based Guidelines for Interventions in Portal Hypertension and Its Complications.

Authors:  Amar Mukund; Shaleen Rana; Chander Mohan; Naveen Kalra; Sanjay Saran Baijal
Journal:  Indian J Radiol Imaging       Date:  2022-01-10

4.  Use of Intravascular Ultrasound to Improve Diagnosis and Treatment of Transjugular Intrahepatic Portosystemic Shunt Dysfunction in Patients in the Long-term Follow-up.

Authors:  Daniele Morosetti; Ilaria Lenci; Renato Argirò; Martina Milana; Fulvio Gasparrini; Sara Crociati; Giuseppe Tisone; Roberto Floris; Leonardo Baiocchi
Journal:  Euroasian J Hepatogastroenterol       Date:  2022 Jan-Jun

5.  Anatomic Variations of the Right Portal Vein: Prevalence, Imaging Features, and Implications for Successful Transjugular Intrahepatic Portosystemic Shunt Creation.

Authors:  Senthil S Gunasekaran; Ron C Gaba
Journal:  J Clin Imaging Sci       Date:  2017-03-28

Review 6.  Transjugular intrahepatic portosystemic shunt in cirrhosis: An exhaustive critical update.

Authors:  Sasidharan Rajesh; Tom George; Cyriac Abby Philips; Rizwan Ahamed; Sandeep Kumbar; Narain Mohan; Meera Mohanan; Philip Augustine
Journal:  World J Gastroenterol       Date:  2020-10-07       Impact factor: 5.742

Review 7.  Advanced portal venous access techniques for transjugular intrahepatic portosystemic shunt placement.

Authors:  Sasan Partovi; Xin Li; Omar Shwaiki; Basem Rashwan; Christer Ruff; Gerd Grozinger; Sameer Gadani; Diane Szaflarski; Dustin Thompson; Guiseppe D'Amico; Abraham Levitin; Baljendra Kapoor
Journal:  BMJ Open Gastroenterol       Date:  2021-12

Review 8.  North American Practice-Based Recommendations for Transjugular Intrahepatic Portosystemic Shunts in Portal Hypertension.

Authors:  Justin R Boike; Bartley G Thornburg; Sumeet K Asrani; Michael B Fallon; Brett E Fortune; Manhal J Izzy; Elizabeth C Verna; Juan G Abraldes; Andrew S Allegretti; Jasmohan S Bajaj; Scott W Biggins; Michael D Darcy; Maryjane A Farr; Khashayar Farsad; Guadalupe Garcia-Tsao; Shelley A Hall; Caroline C Jadlowiec; Michael J Krowka; Jeanne Laberge; Edward W Lee; David C Mulligan; Mitra K Nadim; Patrick G Northup; Riad Salem; Joseph J Shatzel; Cathryn J Shaw; Douglas A Simonetto; Jonathan Susman; K Pallav Kolli; Lisa B VanWagner
Journal:  Clin Gastroenterol Hepatol       Date:  2021-07-15       Impact factor: 13.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.