Literature DB >> 27356009

Biomechanical study of distal radioulnar joint ballottement test.

Tadanobu Onishi1, Shohei Omokawa2, Akio Iida1, Yasuaki Nakanishi1, Tsutomu Kira1, Hisao Moritomo3, Sompob Ruxasagluwang4, Jirchart Kraisarin4, Takamasa Shimizu1, Yasuhito Tanaka1.   

Abstract

We investigated the reliability and accuracy of the distal radioulnar joint (DRUJ) ballottement test using five fresh-frozen cadaver specimens in triangular fibrocartilage complex (TFCC)-intact, and TFCC-sectioned wrists. The humerus and proximal ulna were fixed. The ulna was allowed to translate in dorsopalmar directions without rotation, and the radius was allowed to move freely. Four sensors of a magnetic tracking system were attached to the radius and ulna, and the nails of each examiner's thumbs. Five examiners conducted the DRUJ ballottement test before and after TFCC sectioning. We used two techniques: With holding and without holding the carpal bones to the radius (holding and non-holding tests, respectively). We compared the magnitudes of bone-to-bone (absolute DRUJ) movement with that of the examiner's nail-to-nail (relative DRUJ) movement. The intrarater intraclass correlation coefficients (ICCs) were 0.92 (holding) and 0.94 (non-holding). The interrater ICCs were 0.84 (holding) and 0.75 (non-holding). Magnitudes of absolute and relative movements averaged 11.5 and 11.8 mm, respectively (p < 0.05). Before TFCC sectioning, the DRUJ movement during the holding and non-holding techniques averaged 9.8 and 10.8 mm, respectively (p < 0.05). The increase in DRUJ movement after TFCC sectioning was greater with the holding technique (average 2.3 mm) than with the non-holding technique (average 1.6 mm). The DRUJ ballottement test with magnetic markers is relatively accurate and reliable for detecting unstable joints. We recommend the holding technique for assessing DRUJ instability in clinical practice.
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1123-1127, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Keywords:  ballottement test; biomechanics; distal radioulnar joint; human cadaver

Mesh:

Year:  2016        PMID: 27356009     DOI: 10.1002/jor.23355

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  9 in total

1.  A Biomechanical Perspective on Distal Radioulnar Joint Instability.

Authors:  Shohei Omokawa; Akio Iida; Kenji Kawamura; Yasuaki Nakanishi; Takamasa Shimizu; Tsutomu Kira; Tadanobu Onishi; Naoki Hayami; Yasuhito Tanaka
Journal:  J Wrist Surg       Date:  2017-03-22

Review 2.  Ulnar-sided wrist pain in the athlete (TFCC/DRUJ/ECU).

Authors:  Eric Quan Pang; Jeffrey Yao
Journal:  Curr Rev Musculoskelet Med       Date:  2017-03

3.  Changes in Ulnar Variance after a Triangular Fibrocartilage Complex Tear.

Authors:  Jung-In Shim; Jin-Hyung Im; Joo-Yup Lee; Han-Vit Kang; Sung-Hyun Cho
Journal:  J Wrist Surg       Date:  2018-08-17

4.  Application of force-monitor ultrasonography to assess distal radioulnar joint instability in patients with triangular fibrocartilage complex injury.

Authors:  Hiroshi Yuine; Yuichi Yoshii; Koichi Iwai; Tomoo Ishii; Hideki Shiraishi
Journal:  Ultrasound       Date:  2021-08-25

5.  Distal radioulnar joint kinematics before surgery and 12 months following open foveal reinsertion of the triangular fibrocartilage complex: comparison with the contralateral non-injured joint.

Authors:  Janni K Thillemann; Sepp De Raedt; Emil T Petersen; Katriina B Puhakka; Torben B Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2022-06-21       Impact factor: 3.925

6.  Stabilization of the Distal Radioulnar Joint with or without Triangular Fibrocartilage Complex Tear by an External Wrist Band Brace: A Cadaveric Study.

Authors:  Seung-Han Shin; Taeyong Park; Eunah Hong; Dai-Soon Kwak; Yang-Guk Chung
Journal:  Healthcare (Basel)       Date:  2022-04-30

7.  Proximal Horizontal Flap Tears of TFCC Diagnosed by Computed Tomography Arthrography: Six Case Series.

Authors:  Sayuri Arimitsu; Takashi Masatomi; Atsuo Shigi; Chikako Yukioka; Hisao Moritomo
Journal:  J Wrist Surg       Date:  2020-10-14

8.  Distal radioulnar joint stabilization with open foveal reinsertion versus tendon graft reconstruction: an experimental study using radiostereometry.

Authors:  Janni Kjærgaard Thillemann; Sepp De Raedt; Torben Bæk Hansen; Bo Munk; Maiken Stilling
Journal:  J Exp Orthop       Date:  2021-02-04

9.  A new quantitative evaluation system for distal radioulnar joint instability using a three-dimensional electromagnetic sensor.

Authors:  Shintaro Mukohara; Yutaka Mifune; Atsuyuki Inui; Hanako Nishimoto; Takashi Kurosawa; Kohei Yamaura; Tomoya Yoshikawa; Issei Shinohara; Yuichi Hoshino; Kouki Nagamune; Ryosuke Kuroda
Journal:  J Orthop Surg Res       Date:  2021-07-14       Impact factor: 2.359

  9 in total