Literature DB >> 27350379

The pericardial reflection and the tip of the central venous catheter - topographical analysis in stillborn babies.

Frank Eifinger1, Anne Vierzig2, Bernhard Roth2, Martin Scaal3, Friederike Koerber4.   

Abstract

BACKGROUND: Central venous cannulation is widely used in neonatal critical care. Pericardial tamponade caused by vessel wall perforation can occur if the catheter tip induces extravasation at the level of the pericardium.
OBJECTIVE: To investigate the level of the superior pericardial reflection in stillborn babies.
MATERIALS AND METHODS: We dissected 20 bodies (11 female, mean gestational age 33 6/7 weeks, range 25-43 weeks), with careful opening of the thoracic area. After injecting contrast medium into the pericardial sac, we introduced a catheter through the right internal jugular vein. We then took radiographs to analyse the relationship between visual osseous landmarks and the pericardium.
RESULTS: Mean distance between the pericardial reflection at its upper end and the first thoracic vertebra was 1.3 cm (standard deviation [SD]: 0.3 cm) and did not extend over the 3rd intercostal space. The mean distance from the entry of the superior vena cava into the pericardial sac and the 1st thoracic vertebra was 2.3 cm (SD: 0.5).
CONCLUSION: The upper end of the pericardial reflection in neonates at autopsy lies below the middle of the 3rd thoracic vertebra. The tip of an upper inserted catheter should not extend below the level of the 3rd intercostal space.

Entities:  

Keywords:  Central venous catheter; Complications; Foetus; Neonate; Pericardium; Radiography; Right atrium; Stillbirth; Superior vena cava

Mesh:

Substances:

Year:  2016        PMID: 27350379     DOI: 10.1007/s00247-016-3659-y

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  13 in total

1.  Optimal prediction of the central venous catheter insertion depth on a routine chest x-ray.

Authors:  Yumiko Uchida; Masaki Sakamoto; Hiroki Takahashi; Yoichi Matsuo; Hitoshi Funahashi; Hiroshi Sasano; Kazuya Sobue; Hiromitsu Takeyama
Journal:  Nutrition       Date:  2010-10-08       Impact factor: 4.008

2.  Fetal clavicle length throughout gestation: a nomogram.

Authors:  D M Sherer; M Sokolovski; M Dalloul; F Khoury-Collado; J A Osho; M D Lamarque; O Abulafia
Journal:  Ultrasound Obstet Gynecol       Date:  2006-03       Impact factor: 7.299

Review 3.  Rare but serious complications of central line insertion.

Authors:  Johanna R Askegard-Giesmann; Donna A Caniano; Brian D Kenney
Journal:  Semin Pediatr Surg       Date:  2009-05       Impact factor: 2.754

4.  In vitro evaluation of relative perforating potential of central venous catheters: comparison of materials, selected models, number of lumens, and angles of incidence to simulated membrane.

Authors:  N Gravenstein; R H Blackshear
Journal:  J Clin Monit       Date:  1991-01

5.  Topographical anatomy of central venous system in extremely low-birth weight neonates less than 1000 grams and the effect of central venous catheter placement.

Authors:  F Eifinger; K Brisken; B Roth; J Koebke
Journal:  Clin Anat       Date:  2011-06-03       Impact factor: 2.414

Review 6.  Pericardial reflection around the venous aspect of the heart.

Authors:  P Chaffanjon; P Y Brichon; C Faure; J J Favre
Journal:  Surg Radiol Anat       Date:  1997       Impact factor: 1.246

7.  Cardiac complications in preterm infants with percutaneous long lines: the importance of early diagnosis.

Authors:  Francesca Paola Fusco; Maria Pia De Carolis; Simonetta Costa; Gabriella De Rosa; Annaluce Zambraro; Costantino Romagnoli
Journal:  Resuscitation       Date:  2008-10-25       Impact factor: 5.262

8.  Pericardial effusion and cardiac tamponade in neonates: sudden unexpected death associated with total parenteral nutrition via central venous catheterization.

Authors:  Mikako Warren; Karen S Thompson; Edwina J Popek; Hannes Vogel; John Hicks
Journal:  Ann Clin Lab Sci       Date:  2013       Impact factor: 1.256

9.  Positioning internal jugular venous catheters using the right third intercostal space in children.

Authors:  K O Kim; J O Jo; H S Kim; C S Kim
Journal:  Acta Anaesthesiol Scand       Date:  2003-11       Impact factor: 2.105

10.  The physical dimensions of the human neonatal cardiovascular system.

Authors:  R M Lofthus; H H Srebnik
Journal:  J Biomech Eng       Date:  1987-11       Impact factor: 2.097

View more
  1 in total

1.  [Correct positioning of central venous catheters in pediatrics : Are current formulae really useful?]

Authors:  C Cleff; M Boensch; F Eifinger; J Hinkelbein
Journal:  Anaesthesist       Date:  2018-07       Impact factor: 1.041