Literature DB >> 27347824

Repeatability and reproducibility of right ventricular Tei index valves derived from three echocardiographic methods for evaluation of cardiac function in dogs.

Tomoya Morita, Kensuke Nakamura, Tatsuyuki Osuga, Sue Yee Lim, Nozomu Yokoyama, Keitaro Morishita, Hiroshi Ohta, Mitsuyoshi Takiguchi.   

Abstract

OBJECTIVE To evaluate repeatability and reproducibility of right ventricular Tei index (RTX) values derived from dual pulsed-wave Doppler, conventional pulsed-wave Doppler, and tissue Doppler echocardiography and to investigate relationships and repeatability among the 3 methods in healthy dogs. ANIMALS 6 healthy adult Beagles. PROCEDURE Echocardiography was performed on each dog on different days for 2 weeks (3 times/d) by 2 echocardiographers. Intraobserver within- and between-day and interobserver coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) for RTXs derived from dual pulse-waved Doppler (RTXDPD), conventional pulsed-wave Doppler (RTXPD), and tissue Doppler (RTXTD) methods were determined. Degrees of agreement among RTX values derived from the 3 methods were assessed by modified Bland-Altman analysis. RESULTS Least squares mean (95% confidence interval) RTXtd was 0.50 (0.46 to 0.54), which was significantly higher than that for RTXDPD (0.27 [0.23 to 0.31]) and RTXPD (0.25 [0.21 to 0.29]). Agreement between RTXDPD and RTXPD was good (bias [mean difference], 0.04 [95% confidence interval, -0.03 to 0.10]). The RTXdpd had high within-day (CV, 6.1; ICC, 0.77) and interobserver (CV, 3.5; ICC, 0.83) repeatability, but between-day repeatability was not high. The RTXtd had high within-day repeatability (CV, 6.0; ICC, 0.80), but between-day and interobserver repeatability were not high. Within-day, between-day, and interobserver repeatability of RTXPD were not high. CONCLUSIONS AND CLINICAL RELEVANCE RTXdpd measurement was a repeatable and reproducible method of cardiac evaluation in healthy dogs. The RTXTD values were significantly higher than the RTXDPD and RTXPD values; therefore, RTX values derived from different echocardiographic methods should be interpreted with caution.

Entities:  

Mesh:

Year:  2016        PMID: 27347824     DOI: 10.2460/ajvr.77.7.715

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  5 in total

1.  Evaluation of Right Ventricular Function and Dyssynchrony in a Dog Model of Acute Pulmonary Embolism: Diagnostic Utility and Reversibility.

Authors:  Tomoya Morita; Kensuke Nakamura; Tatsuyuki Osuga; Sei Kawamoto; Shingo Miki; Mitsuyoshi Takiguchi
Journal:  Front Vet Sci       Date:  2022-06-20

2.  Pulmonary hypertension due to unclassified interstitial lung disease in a Pembroke Welsh corgi.

Authors:  Tomoya Morita; Kensuke Nakamura; Tatsuyuki Osuga; Atsushi Kobayashi; Osamu Ichii; Akira Yabuki; Mitsuyoshi Takiguchi
Journal:  J Vet Med Sci       Date:  2018-04-23       Impact factor: 1.267

3.  Short-term effects of sildenafil in the treatment of dogs with pulmonary hypertension secondary to degenerative mitral valve disease.

Authors:  Karun Saetang; Sirilak Disatian Surachetpong
Journal:  Vet World       Date:  2020-10-29

4.  Transverse Right Ventricle Strain and Strain Rate Assessed by 2-Dimensional Speckle Tracking Echocardiography in Dogs with Pulmonary Hypertension.

Authors:  Domenico Caivano; Mark Rishniw; Francesco Birettoni; Vasilica-Flory Petrescu; Francesco Porciello
Journal:  Vet Sci       Date:  2020-02-07

5.  A novel index equivalent to the myocardial performance index for right ventricular functional assessment in children and adolescent patients.

Authors:  Yasunobu Hayabuchi; Yukako Homma; Shoji Kagami
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

  5 in total