Literature DB >> 27343785

Comparing insertion characteristics on nasogastric tube placement by using GlideScope™ visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients.

Wan Hafsah Wan Ibadullah1, Nurlia Yahya2, Siti Salmah Ghazali3, Esa Kamaruzaman1, Liu Chian Yong1, Adnan Dan1, Jaafar Md Zain1.   

Abstract

BACKGROUND AND
OBJECTIVE: This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScope™ visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients.
METHODS: Ninety-six ASA I or II patients, aged 18-70 years were recruited and randomized into two groups using either technique. The time taken from insertion of the nasogastric tube from the nostril until the calculated length of tube had been inserted was recorded. The success rate of nasogastric tube insertion was evaluated in terms of successful insertion in the first attempt. Complications associated with the insertion techniques were recorded.
RESULTS: The results showed success rates of 74.5% in the GlideScope™ Group as compared to 58.3% in the MacIntosh Group (p=0.10). For the failed attempts, the nasogastric tube was successfully inserted in all cases using rescue techniques. The duration taken in the first attempt for both techniques was not statistically significant; Group A was 17.2±9.3s as compared to Group B, with a duration of 18.9±13.0s (p=0.57). A total of 33 patients developed complications during insertion of the nasogastric tube, 39.4% in Group A and 60.6% in Group B (p=0.15). The most common complications, which occurred, were coiling, followed by bleeding and kinking.
CONCLUSION: This study showed that using the GlideScope™ to facilitate nasogastric tube insertion was comparable to the use of the MacIntosh laryngoscope in terms of successful rate of insertion and complications.
Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

Entities:  

Keywords:  Complications; Complicações; Direct laryngoscope; Laringoscopia direta; Nasogastric tube; Sonda nasogástrica; Videolaringoscópio; Videolaryngoscope

Mesh:

Year:  2015        PMID: 27343785     DOI: 10.1016/j.bjane.2014.11.013

Source DB:  PubMed          Journal:  Braz J Anesthesiol


  1 in total

1.  Role of Endotracheal Tube Cuff Deflation in Facilitating Passage of Nasogastric Tube.

Authors:  Nidhi Bangarwa; Sumedha Vashishth; Vineet Kumar; Prashant Kumar; Preeti Gehlaut
Journal:  Cureus       Date:  2022-09-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.