"Assessment of effectiveness and security in high pressure postdilatation of bioresorbable vascular scaffolds during percutaneous coronary intervention. Study in a contemporary, non-selected cohort of Spanish patients".

Rosa A Abellas-Sequeiros1, Raymundo Ocaranza-Sanchez2, Carlos Galvão Braga3, Sergio Raposeiras-Roubin2, Diego Lopez-Otero2, Belen Cid-Alvarez2, Pablo Souto-Castro2, Ramiro Trillo-Nouche2, Jose R Gonzalez-Juanatey2.   

Abstract

OBJECTIVES: To determine security and benefits of high pressure postdilatation (HPP) of bioresorbable vascular scaffolds (BVS) in percutaneous coronary intervention (PCI) of complex lesions whatever its indication is.
BACKGROUND: Acute scaffold disruption has been proposed as the main limitation of BVS when they are overexpanded. However, clinical implications of this disarray are not yet clear and more evidence is needed.
METHODS: A total of 25 BVS were deployed during PCI of 14 complex lesions after mandatory predilatation. In all cases HPP was performed with NC balloon in a 1:1 relation to the artery. After that, optical coherence tomography (OCT) analyses were performed.
RESULTS: Mean and maximal postdilatation pressure were 17±3.80 and 20 atmospheres (atm) respectively. Postdilatation balloon/scaffold diameter ratio was 1.01. A total of 39,590 struts were analyzed. Mean, minimal and maximal scaffold diameter were respectively: 3.09±0.34mm, 2.88±0.31mm and 3.31±0.40mm. Mean eccentricity index was 0.13±0.05. ISA percentage was 1.42% with a total of 564 malapposed struts. 89 struts were identified as disrupted, which represents a percentage of disrupted struts of 0.22%. At 30days, none of our patients died, suffered from stroke, stent thrombosis or needed target lesion revascularization (TLR).
CONCLUSIONS: NC balloon HPP of BVS at more than 17atm (up to 20atm) is safe during PCI and allows to achieve better angiographic and clinical results.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Bioresorbable vascular scaffolds; OCT; PCI; STEMI

Mesh:

Year:  2016        PMID: 27343418     DOI: 10.1016/j.ijcard.2016.06.029

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  2 in total

1.  Bioresorbable vascular scaffolds in coronary chronic total occlusions revascularization: safety assessment related to struts coverage and apposition in 6-month OCT follow-up.

Authors:  Rosa Alba Abellas-Sequeiros; Raymundo Ocaranza-Sanchez; Ramiro Trillo-Nouche; Carlos Gonzalez-Juanatey; Jose Ramon Gonzalez-Juanatey
Journal:  Heart Vessels       Date:  2017-04-21       Impact factor: 2.037

2.  The Clinical and Angiographic Outcomes of Postdilation after Percutaneous Coronary Intervention in Patients with Acute Coronary Syndrome: A Systematic Review and Meta-Analysis.

Authors:  Yan Li; Xiying Liang; Wenjiao Zhang; Xuan Qiao; Zhilu Wang
Journal:  J Interv Cardiol       Date:  2021-04-09       Impact factor: 2.279

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.