Literature DB >> 27338510

Can an adjustable-loop length suspensory fixation device reduce femoral tunnel enlargement in anterior cruciate ligament reconstruction? A prospective computer tomography study.

R M Lanzetti1, E Monaco2, A De Carli2, A Grasso3, A Ciompi2, R Sigillo2, G Argento4, A Ferretti2.   

Abstract

BACKGROUND: The aim of this study was to compare bone femoral tunnel enlargement in patients who underwent anterior cruciate ligament (ACL) transtibial reconstruction using an adjustable-loop length suspensory fixation device and a fixed-loop length suspensory fixation device.
METHODS: All patients treated for ACL reconstruction with an ipsilateral hamstring between March 2013 and March 2014 were evaluated. Subjects were assigned to Group A (TightRope™ (TR) femoral fixation) or Group B (EndoButton® (EB) femoral fixation). All patients were evaluated with the Lachman test, pivot-shift test, 2000 International Knee Documentation Committee (IKDC) knee examination and KT1000 arthrometer. The subjective evaluation was performed using the 2000 IKDC Subjective Knee score, the Lysholm knee score, and the Tegner activity scale. CT examination was performed to evaluate femoral tunnel enlargement at four different levels. All patients were assessed at a 12month follow-up visit. Power analysis was performed a priori in accordance with the femoral tunnel enlargement values from the CT scans. Differences with P-values of ≤0.05 were considered to be statistically significant.
RESULTS: The groups were homogenous at baseline with regard to age, gender, BMI, dominance and disease duration. At the final follow-up, no statistically significant differences (P>0.05) were found according to subjective and objective clinical outcome measures. According to the femoral tunnel enlargement, no statistically significant difference was found between the two groups (P>0.05).
CONCLUSION: In transtibial ACL reconstruction, the use of a fixed or adjustable-loop length device products, on the femoral side, led to similar clinical and radiological results.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  ACL; Femoral tunnel; Suspensory fixation device; Tunnel widening

Mesh:

Year:  2016        PMID: 27338510     DOI: 10.1016/j.knee.2016.01.015

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  12 in total

1.  Adjustable-loop implants are non-inferior to fixed-loop implants for femoral fixation in anterior cruciate ligament reconstruction.

Authors:  Simone B Elmholt; Torsten G Nielsen; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-06-23       Impact factor: 4.342

2.  [Lengths of the fixed loop and the adjustable loop in the coarse bone tunnel were compared to influence the widening of the femoral bone tunnel and the function of the knee joint].

Authors:  Y Yin; Y Mei; Z G Wang; S Y Song; P F Liu; P F He; W J Wu; X Xie
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2021-10-18

3.  Comparison of Fixed- and Variable-Loop Button Fixation in Arthroscopic Anterior Cruciate Ligament Reconstruction.

Authors:  Vijay Chandru; Santhosh M S; Sujana Theja J S; Rohit R Nair
Journal:  Cureus       Date:  2022-04-17

Review 4.  Fixed-loop vs. adjustable-loop cortical button devices for femoral fixation in ACL reconstruction - a systematic review and meta-analysis.

Authors:  Simone Birkebæk Elmholt; Torsten Grønbech Nielsen; Martin Lind
Journal:  J Exp Orthop       Date:  2022-10-21

5.  TightRope Versus Biocomposite Interference Screw for Fixation in Allograft ACL Reconstruction: Prospective Evaluation of Osseous Integration and Patient Outcomes.

Authors:  Shahram Shawn Yari; Ashraf N El Naga; Amar Patel; Ali Asaf Qadeer; Anup Shah
Journal:  JB JS Open Access       Date:  2020-04-02

6.  Is all-inside with suspensory cortical button fixation a superior technique for anterior cruciate ligament reconstruction surgery? A systematic review and meta-analysis.

Authors:  Chun-Wei Fu; Wei-Cheng Chen; Yung-Chang Lu
Journal:  BMC Musculoskelet Disord       Date:  2020-07-07       Impact factor: 2.362

7.  Comparison of the aperture and midportion femoral tunnel widening after anterior cruciate ligament reconstruction: A systematic review and meta-analyses.

Authors:  Haluk Celik; Dae-Hee Lee
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

Review 8.  Femoral Tunnel Widening Via Transcondylar Cross-Pin Fixation Versus Extracortical Suspensory Fixation After Single-Bundle ACLR: A Systematic Review and Meta-analysis.

Authors:  Haluk Celik; Jun-Ho Kim; Sang-Hak Lee; Dae-Hee Lee
Journal:  Orthop J Sports Med       Date:  2021-04-02

9.  A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixation.

Authors:  Naiyer Asif; Mohammad Jesan Khan; K P Haris; Shah Waliullah; Anubhav Sharma; Danish Firoz
Journal:  Knee Surg Relat Res       Date:  2021-12-04

Review 10.  Adjustable Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

Authors:  Sarvpreet Singh; Shalin Shaunak; Sebastian C K Shaw; John L Anderson; Vipul Mandalia
Journal:  Indian J Orthop       Date:  2020-01-13       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.