Literature DB >> 27337742

Comparison of four immunoassays to measure serum ferritin concentrations and iron deficiency prevalence among non-pregnant Cambodian women and Congolese children.

Crystal D Karakochuk, Kyly C Whitfield, Aviva I Rappaport, Susan I Barr, Suzanne M Vercauteren, Judy McLean, Kroeun Hou, Aminuzzaman Talukder, Lisa A Houghton, Karl B Bailey, Erick Boy, Timothy J Green.   

Abstract

BACKGROUND: Global standardization of ferritin assays is lacking, which could have direct implications on the accurate measurement and comparability of ferritin concentration and iron deficiency (ID) prevalence rates in at-risk populations.
METHODS: We measured serum ferritin concentrations using four immunoassays: the s-ELISA and the AxSYM™ analyzer were compared among 420 non-pregnant Cambodian women; the Centaur® XP analyzer, s-ELISA, and AxSYM™ analyzer were compared among a subset of 100 Cambodian women; and the s-ELISA and the Elecsys® 2010 analyzer were compared among 226 Congolese children aged 6-59 months.
RESULTS: Median ferritin concentrations (adjusted for inflammation) ranged between 48 and 91 μg/L among Cambodian women and between 54 and 55 μg/L among Congolese children. ID prevalence ranged from 2% to 10% among Cambodian women and 5% to 7% among Congolese children. Bias between methods varied widely (-9 to 45 μg/L) among women, and was 43 μg/L among children. Bias was lower when ferritin values outside of the s-ELISA measurement range (>250 μg/L) were excluded.
CONCLUSIONS: The observed differences in ferritin concentrations likely reflect different ferritin isoforms, antibodies, and calibrators used across assays and by different laboratories. However, despite differences in ferritin concentrations, ID prevalence was relatively similar and low across all methods.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27337742     DOI: 10.1515/cclm-2016-0421

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

1.  Measuring plasma ferritin levels with two different methods: A comparison of Roche Cobas e601 versus Roche Cobas c501 (integrated modular system Roche Cobas 6000).

Authors:  Durmuş Ayan; Sibel Soylemez
Journal:  J Med Biochem       Date:  2020-01-10       Impact factor: 3.402

2.  Growth patterns of infants with in- utero HIV and ARV exposure in Cape Town, South Africa and Lusaka, Zambia.

Authors:  Dorothy C Nyemba; Emma Kalk; Michael J Vinikoor; Hlengiwe P Madlala; Mwangelwa Mubiana-Mbewe; Maureen Mzumara; Carolyn Bolton Moore; Amy L Slogrove; Andrew Boulle; Mary-Ann Davies; Landon Myer; Kathleen Powis
Journal:  BMC Public Health       Date:  2022-01-10       Impact factor: 4.135

3.  A Comparative Study for Measuring Serum Ferritin Levels with Three Different Laboratory Methods: Enzyme-Linked Immunosorbent Assay versus Cobas e411 and Cobas Integra 400 Methods.

Authors:  Lotfi S Bin Dahman; Khalid M Sumaily; Essa M Sabi; Mohammed A Hassan; Abeer M Bin Thalab; Asrar S Sayad; Saleh M Bin Kolaib; Fatima M Alhadhrmi
Journal:  Diagnostics (Basel)       Date:  2022-01-27

4.  Comparison of a New Multiplex Immunoassay for Measurement of Ferritin, Soluble Transferrin Receptor, Retinol-Binding Protein, C-Reactive Protein and α¹-Acid-glycoprotein Concentrations against a Widely-Used s-ELISA Method.

Authors:  Crystal D Karakochuk; Amanda M Henderson; Kaitlyn L I Samson; Abeer M Aljaadi; Angela M Devlin; Elodie Becquey; James P Wirth; Fabian Rohner
Journal:  Diagnostics (Basel)       Date:  2018-02-02

Review 5.  Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.

Authors:  Maria N Garcia-Casal; Juan P Peña-Rosas; Eloisa Urrechaga; Jesus F Escanero; Junsheng Huo; Ricardo X Martinez; Lucero Lopez-Perez
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240

6.  A sandwich enzyme-linked immunosorbent assay for the quantitation of human plasma ferritin.

Authors:  Andie V Bleicher; Holger W Unger; Stephen J Rogerson; Elizabeth H Aitken
Journal:  MethodsX       Date:  2018-06-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.