Lukas Fricker1, Vincenzo Penna1, Florian Lampert1, G Bjoern Stark1, Christian Witzel2, Georgios Koulaxouzidis1.
Abstract
The sciatic functional index (SFI) is a popular parameter for peripheral nerve evaluation that relies on footprints obtained with ink and paper. Drawbacks include smearing artefacts and a lack of dynamic information during measurement. Modern applications use digitized systems that can deliver results with less analytical effort and fewer mice. However, the systems are expensive (€40,000). This study aimed to evaluate the applicability and precision of a self-made, low-cost infrared system for evaluating SFI in mice. Mice were subjected to unilateral sciatic nerve crush injury (crush group; n = 7) and sham operation (sham group; n = 4). They were evaluated on the day before surgery, the 2(nd), 4(th) and 6(th) days after injury, and then every day up to the 23(rd) day after injury. We compared two SFI evaluation methods, i.e., conventional ink-and-paper SFI (C-SFI) and our infrared system (I-SFI). Our apparatus visualized footprints with totally internally reflected infrared light (950 nm) and a camera that can only detect this wavelength. Additionally we performed an analysis with the ladder beam walking test (LBWT) as a reference test. I-SFI assessment reduced the standard deviation by about 33 percent, from 11.6 to 7.8, and cut the variance around the baseline to 21 percent. The system thus requires fewer measurement repetitions and fewer animals, and cuts the cost of keeping the animals. The apparatus cost €321 to build. Our results show that the process of obtaining the SFI can be made more precise via digitization with a self-made, low-cost infrared system.Entities:
Keywords: crush; error rate; frustrated total internal reflection; infrared; ladder beam walking test; mouse; nerve regeneration; neural regeneration; peripheral nerve injury; sciatic nerve
Year: 2016 PMID: 27335570 PMCID: PMC4904477 DOI: 10.4103/1673-5374.182712
Source DB: PubMed Journal: Neural Regen Res ISSN: 1673-5374 Impact factor: 5.135
Figure 4Diagram and principle of the infrared system (I-SFI) capturing apparatus.
(A) 36 light-emitting diodes are wired in four series of nine bulbs, with a resistor (100 Ω). The series are wired in parallel to a power supply (12 V, 15 W). (B) The light is only allowed to enter the acrylic sheet from the edges. Frustrated total internal reflection means that the light becomes trapped between the two surfaces of the acrylic sheet. (C) When an object touches the surface of the acrylic sheet, the light is allowed to leave. This illuminates the object and allows the webcam to see it.
Correlation of SFI evaluation methods with the LBWT