Literature DB >> 27334759

Temperature measurement in the adult emergency department: oral, tympanic membrane and temporal artery temperatures versus rectal temperature.

Polly E Bijur1, Purvi D Shah1, David Esses1.   

Abstract

OBJECTIVE: The objective was to compare agreement between three non-invasive measures of temperature and rectal temperatures and to estimate the sensitivity and specificity of these measures to detect a rectal temperature of 38°C or higher.
METHODS: We conducted a study of the diagnostic accuracy of oral, tympanic membrane (TM) and temporal artery (TA) thermometry to measure fever in an urban emergency department (ED). Data were collected from adult patients who received rectal temperature measurement. Bland-Altman analysis was performed; sensitivity, specificity and 95% CIs were calculated.
RESULTS: 987 patients were enrolled. 36% of the TM and TA readings differed by 0.5°C or more from rectal temperatures, 50% of oral temperatures. TM measures were most precise-the SD of the difference from rectal was 0.4°C TM, and 0.6°C for oral and TA (p<0.001). The sensitivities of a 38°C cutpoint on oral, TM and TA measures to detect a rectal temperature of 38°C or higher were: 37.0%, 68.3% and 71.1%, respectively (oral vs TM and TA p<0.001). The corresponding specificities were 99.4%, 98.2% and 92.3% (oral, TM and TA) with oral specificity significantly higher than the other two methods (p<0.01). TM and TA cutpoints of 37.5°C provided greater than 90% sensitivity to detect fever with specificity of 90% and 72%, respectively.
CONCLUSIONS: None of the non-invasive methods met benchmarks for diagnostic accuracy using the criterion of 38°C to detect rectal temperature of 38°C. A TM cutpoint of 37.5°C provides maximum diagnostic accuracy of the three non-invasive measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

Entities:  

Keywords:  clinical assessment; emergency department; equipment evaluation

Mesh:

Year:  2016        PMID: 27334759     DOI: 10.1136/emermed-2015-205122

Source DB:  PubMed          Journal:  Emerg Med J        ISSN: 1472-0205            Impact factor:   2.740


  6 in total

1.  Regression Model for Predicting Core body Temperature in Infrared Thermal Mass Screening.

Authors:  Chayabhan Limpabandhu; Frances Sophie Woodley Hooper; Rui Li; Zion Tse
Journal:  IPEM Transl       Date:  2022-07-15

2.  Ear measurement of temperature is only useful for screening for fever in an adult emergency department.

Authors:  Christian Backer Mogensen; Malene Bue Vilhelmsen; Johanne Jepsen; Lilian Keene Boye; Maiken Hjuler Persson; Florence Skyum
Journal:  BMC Emerg Med       Date:  2018-12-03

3.  Life-threatening heat-related illness with severe hyponatremia in an aluminum smelter worker.

Authors:  James C Wesdock; A Michael Donoghue
Journal:  Am J Ind Med       Date:  2019-10-24       Impact factor: 2.214

Review 4.  The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis.

Authors:  Valentina Pecoraro; Davide Petri; Giorgio Costantino; Alessandro Squizzato; Lorenzo Moja; Gianni Virgili; Ersilia Lucenteforte
Journal:  Intern Emerg Med       Date:  2020-11-25       Impact factor: 3.397

5.  The non-contact handheld cutaneous infra-red thermometer for fever screening during the COVID-19 global emergency.

Authors:  J Aw
Journal:  J Hosp Infect       Date:  2020-02-21       Impact factor: 3.926

6.  Studying the Accuracy and Function of Different Thermometry Techniques for Measuring Body Temperature.

Authors:  Aaron James Mah; Leili Ghazi Zadeh; Mahta Khoshnam Tehrani; Shahbaz Askari; Amir H Gandjbakhche; Babak Shadgan
Journal:  Biology (Basel)       Date:  2021-12-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.