Literature DB >> 27334106

Single-center experience with simultaneous thoracic endovascular aortic repair and abdominal endovascular aneurysm repair.

Qinglong Zeng1, Xi Guo2, Lianjun Huang2, Lizhong Sun1.   

Abstract

Objective To evaluate the efficacy and outcomes of simultaneous thoracic endovascular aortic repair (TEVAR) and abdominal endovascular aneurysm repair (EVAR). Methods A total of 21 patients (20 men; mean 65 ± 7 years, range 54-77) underwent simultaneous TEVAR and EVAR between September 2010 and June 2015 at a single center were retrospectively reviewed. All patients had concomitant thoracic pathologies (aneurysm, penetrating aortic ulcer, intramural hematoma, or dissection) and abdominal aortic aneurysm. The abdominal aneurysms diameters ranged from 5.9 cm to 10 cm. Thoracic lesions in 17 patients were complicated with acute aortic syndrome, and the remainders had indications for simultaneous repair. All patients were followed up postoperative at 1 month, 6 months, and yearly thereafter. Technique success, procedure-related complications were evaluated. Results All patients received local anesthesia, perioperative relative high arterial pressure (above 130/80 mmHg) maintenance, and prophylactic high-dose corticosteroid. The technical success rate was 100%. Average procedural time was 157.6 ± 45.6 min. The length of thoracic coverage was 20.4 ± 4.7 cm (range 15-27). Two patients required left subclavian artery coverage during TEVAR and two patients required lowest renal artery coverage during EVAR. Chimney stents were deployed simultaneously. Patients were followed between 2 and 59 months postoperatively. No patients developed acute cardiopulmonary complications and contrast-induced nephropathy. Two patients developed transient lower extremity weakness that resolved with blood pressure elevation, cerebrospinal fluid drainage, and intravenous drips of high-dose corticosteroid. The average hospital stay was 10.7 ± 7.9 days (range 4-30). During follow-up, one patient died of aneurysm rupture at postoperative 6 months, two patients developed type Ib endoleak at 9 months and 48 months respectively, one was successfully sealed with iliac stent-graft extension, the other received conservative treatment and is symptom free till now. Conclusion Combined TEVAR and EVAR can be performed safely with minimal morbidity and mortality. When anatomically feasible, simultaneous TEVAR and EVAR can be considered as an acceptable alternative for multilevel aortic diseases.

Entities:  

Keywords:  Thoracic aorta; abdominal aorta; aneurysm; dissection; endovascular aneurysm repair; penetrating aortic ulcer; spinal cord ischemia; thoracic endovascular aortic repair

Mesh:

Year:  2016        PMID: 27334106     DOI: 10.1177/1708538116651020

Source DB:  PubMed          Journal:  Vascular        ISSN: 1708-5381            Impact factor:   1.285


  4 in total

1.  Early and midterm outcomes of thoracic endovascular aortic repair (TEVAR) for acute and chronic complicated type B aortic dissection.

Authors:  Min-Hong Zhang; Xin Du; Wei Guo; Xiao-Ping Liu; Xin Jia; Yang-Yang Ge
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

2.  Stent graft in abdominal aortic aneurysm collapsed suddenly after thoracic endovascular aortic repair.

Authors:  Sho Takagi; Yoshihiro Goto; Junji Yanagisawa; Akio Nakasu
Journal:  BMJ Case Rep       Date:  2021-12-09

3.  Incidence, follow-up and outcomes of incidental abdominal aortic aneurysms in computed tomography.

Authors:  Fehim Can Sevil; Mehmet Tort; Çiğdem Özer Gökaslan; Hülya Sevil; Necip Becit
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-03-31

4.  Successful short interval staged surgery in synchronous type A aortic dissection and giant abdominal aortic aneurysm patient.

Authors:  Zhipeng Hu; Zhiwei Wang; Xinping Min; Bowen Li; Min Zhang; Feifeng Dai; Xin Cai
Journal:  Heliyon       Date:  2022-10-06
  4 in total