Literature DB >> 27329164

Use of pre-intervention imaging with a novel image fusion software for guidance of cardiac catheterisation in a patient with pulmonary atresia and major aortopulmonary collaterals.

Sebastian Goreczny1, Pawel Dryzek1, Tomasz Moszura1.   

Abstract

We present a 3.5-year-old patient with tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collaterals, after repeat implantation of a central shunt, in whom we successfully re-purposed previous imaging scans with a novel image fusion software to guide diagnostic heart catheterisation. The pre-registered CT scan was segmented before the procedure and subsequently manually fused with two-dimensional fluoroscopy images. The overlaid roadmap enhanced selective cannulation of all major vessels originating from the aorta, making aortography unnecessary.

Entities:  

Keywords:  3D roadmap; Image fusion; VesselNavigator

Mesh:

Year:  2016        PMID: 27329164     DOI: 10.1017/S1047951116000895

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  5 in total

1.  Novel Three-Dimensional Image Fusion Software to Facilitate Guidance of Complex Cardiac Catheterization : 3D image fusion for interventions in CHD.

Authors:  Sebastian Goreczny; Pawel Dryzek; Gareth J Morgan; Maciej Lukaszewski; Jadwiga A Moll; Tomasz Moszura
Journal:  Pediatr Cardiol       Date:  2017-05-27       Impact factor: 1.655

Review 2.  Pros, cons and future perspectives - three questions on three dimensional guidance for cardiac catheterization in congenital heart disease.

Authors:  Sebastian Góreczny; Gregor Krings; Ziyad M Hijazi; Thomas Fagan; Darren Berman; Damien Kenny; Gareth J Morgan
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-04       Impact factor: 1.426

3.  Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance.

Authors:  S Goreczny; T Moszura; P Dryzek; M Lukaszewski; A Krawczuk; J Moll; G J Morgan
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

4.  3D image fusion for live guidance of stent implantation in aortic coarctation - magnetic resonance imaging and computed tomography image overlay enhances interventional technique.

Authors:  Sebastian Goreczny; Pawel Dryzek; Tomasz Moszura; Titus Kühne; Felix Berger; Stephan Schubert
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-09-25       Impact factor: 1.426

5.  Magnetic resonance and computed tomography imaging fusion for live guidance of percutaneous pulmonary valve implantation.

Authors:  Sebastian Góreczny; Paweł Dryżek; Tomasz Moszura; Maciej Łukaszewski; Michał Podgórski; Sarah Nordmeyer; Titus Kuehne; Felix Berger; Stephan Schubert
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-12-11       Impact factor: 1.426

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.