Literature DB >> 27318722

Echocardiographic Ischemic Memory Imaging Through Complement-Mediated Vascular Adhesion of Phosphatidylserine-Containing Microbubbles.

Brian Mott1, William Packwood1, Aris Xie1, J Todd Belcik1, Ronald P Taylor2, Yan Zhao1, Brian P Davidson1, Jonathan R Lindner3.   

Abstract

OBJECTIVES: This study hypothesized that microvascular retention of phosphatidylserine-containing microbubbles (MB-PS) would allow detection of recent but resolved myocardial ischemia with myocardial contrast echocardiographic (MCE) molecular imaging.
BACKGROUND: Techniques for ischemic memory imaging which can detect and spatially assess resolved myocardial ischemia are being developed for rapid evaluation of patients with chest pain.
METHODS: MCE molecular imaging with MB-PS was performed 1.5 h, 3.0 h, and 6.0 h after brief (10 min) myocardial ischemia in mice; data were compared to selectin-targeted microbubbles. MCE molecular imaging with Sonazoid (GE Healthcare, Amersham, United Kingdom), a commercially produced phosphatidylserine (PS) - containing agent, was performed in separate mice at 1.5 h and 3.0 h after ischemia-reperfusion; and in dogs undergoing 135 min of ischemia and 60 min of reflow as well as in closed-chest nonischemic control dogs. The mechanism for MB-PS attachment was assessed by intravital microscopy of post-ischemic muscle and by flow cytometry analysis of cell-MB interactions.
RESULTS: In mice undergoing ischemia-reperfusion without infarction, signal enhancement in the risk area for MB-PS and p-selectin glycoprotein ligand-1-targeted microbubbles was similar at reflow times of 1.5 h (23.3 ± 7.3 IU vs. 30.7 ± 4.1 IU), 3.0 h (42.2 ± 6.2 IU vs. 33.9 ± 7.4 IU), and 6.0 h (24.1 ± 4.3 IU vs. 25.5 ± 4.7 IU). For both agents, signal in the risk area was significantly (p < 0.05) higher than remote region at all reflow times. Sonazoid also produced strong risk area enhancement at 1.5 h (34.7 ± 5.0 IU) and 3.0 h (52.5 ± 4.5 IU) which was approximately 3-fold greater than in the control region, and which correlated spatially with the microsphere-derived risk area. In dogs, Sonazoid signal in the risk area was >5-fold higher than in closed-chest control myocardium (42.2 ± 8.1 IU vs. 7.9 ± 3.3 IU; p < 0.001). Mechanistic studies indicated that MB-PS attached directly to venular endothelium and adherent leukocytes which was dependent on serum complement components C1q and C3.
CONCLUSIONS: Ischemic memory imaging with MCE is possible using MB-PS which may obviate the need for ligand-directed targeting.
Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  complement; microbubbles; myocardial contrast echocardiography; myocardial ischemia; phosphatidylserine

Mesh:

Substances:

Year:  2016        PMID: 27318722     DOI: 10.1016/j.jcmg.2015.11.031

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  6 in total

1.  Molecular Imaging of VWF (von Willebrand Factor) and Platelet Adhesion in Postischemic Impaired Microvascular Reflow.

Authors:  Koya Ozawa; William Packwood; Oleg Varlamov; Yue Qi; Aris Xie; Melinda D Wu; Zaverio Ruggeri; Jose A López; Jonathan R Lindner
Journal:  Circ Cardiovasc Imaging       Date:  2018-11       Impact factor: 7.792

Review 2.  Targeting of microbubbles: contrast agents for ultrasound molecular imaging.

Authors:  Shiying Wang; John A Hossack; Alexander L Klibanov
Journal:  J Drug Target       Date:  2018-01-09       Impact factor: 5.121

3.  Echocardiographic Ischemic Memory Molecular Imaging for Point-of-Care Detection of Myocardial Ischemia.

Authors:  Brian P Davidson; James Hodovan; Michael E Layoun; Harsh Golwala; Firas Zahr; Jonathan R Lindner
Journal:  J Am Coll Cardiol       Date:  2021-11-16       Impact factor: 24.094

Review 4.  Ultrasound molecular imaging: insights into cardiovascular pathology.

Authors:  Koya Ozawa; Jonathan R Lindner
Journal:  J Echocardiogr       Date:  2020-02-13

5.  Evaluation of expression levels and mechanism of complement activation.

Authors:  Xing Wang; An-Heng Liu; Zhong-Wei Jia; Kui Pu; Kang-Yin Chen; Hua Guo
Journal:  Exp Ther Med       Date:  2017-07-26       Impact factor: 2.447

6.  Diagnostic Ultrasound and Microbubbles Treatment Improves Outcomes of Coronary No-Reflow in Canine Models by Sonothrombolysis.

Authors:  Hairui Li; Yongkang Lu; Yili Sun; Gangbin Chen; Junfen Wang; Shifei Wang; Chixiong Huang; Lintao Zhong; Xiaoyun Si; Wangjun Liao; Yulin Liao; Shiping Cao; Jianping Bin
Journal:  Crit Care Med       Date:  2018-09       Impact factor: 7.598

  6 in total