Literature DB >> 27318579

Evaluating an Image Gently and Image Wisely Campaign in a Multihospital Health Care System.

Kevin Fernandes1, Terry L Levin2, Todd Miller3, Alan H Schoenfeld3, E Stephen Amis3.   

Abstract

PURPOSE: The efficacy of an Image Gently(®)/Image Wisely(®) radiology departmental campaign consisting of the optimization of CT protocols to reduce dose while maintaining quality, and an educational effort to alter the ordering patterns of referring physicians at a multihospital academic center, was evaluated.
METHODS: The numbers of CT, MR, and ultrasound studies performed at inpatient, outpatient, and emergency facilities in the hospital system before and after the initiation of the departmental campaign (2010) were obtained for a 10-year period (2004-2014) using a radiology information system. For the same time period, dose per scan (volumetric CT dose index) was obtained through the Dose Index Registry(®)/National Radiology Data Registry for frequently performed studies. Descriptive statistics were used to analyze temporal trends in radiation dose and utilization across differing age groups: <20, 20 to 39, and 40 to 59 years.
RESULTS: The radiology information system yielded 865,879 imaging examinations and 4,508,030 patients. Although patient and imaging volume grew annually over the study period (by 6.8% and 4.9%, respectively), CT utilization as a percentage of total imaging decreased, compensated for by an increase in ultrasound use. This was most marked in the youngest age group. MR use as a percentage of total imaging was unchanged. The median volumetric CT dose index for each study protocol was reduced or stabilized.
CONCLUSIONS: The campaign resulted in a reduction in CT utilization, a reduction in radiation dose per study, and a compensatory rise in ultrasound use. An interactive aggressive educational campaign directed toward referring providers combined with protocol dose reduction efforts can be successful in reducing patient exposure from medical radiation.
Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Image Gently; Image Wisely; Medical radiation; computed tomography; dose

Mesh:

Year:  2016        PMID: 27318579     DOI: 10.1016/j.jacr.2016.04.025

Source DB:  PubMed          Journal:  J Am Coll Radiol        ISSN: 1546-1440            Impact factor:   5.532


  5 in total

Review 1.  Radiation use in diagnostic imaging in children: approaching the value of the pediatric radiology community.

Authors:  Donald P Frush; Erich Sorantin
Journal:  Pediatr Radiol       Date:  2021-03-20

2.  Identification of quality improvement areas in pediatric MRI from analysis of patient safety reports.

Authors:  Camilo Jaimes; Diana J Murcia; Karen Miguel; Cathryn DeFuria; Pallavi Sagar; Michael S Gee
Journal:  Pediatr Radiol       Date:  2017-10-19

3.  Radiation Exposure of Premature Infants Beyond the Perinatal Period.

Authors:  Alexander H Hogan; Eran Bellin; Lindsey Douglas; Terry L Levin; Nora Esteban-Cruciani
Journal:  Hosp Pediatr       Date:  2018-10-09

4.  Evaluation of the impact of a brief educational message on clinicians' awareness of risks of ionising-radiation exposure in imaging investigations: a pilot pre-post intervention study.

Authors:  Ben Young; Jo Cranwell; Andrew W Fogarty; Rob Skelly; Nigel Sturrock; Mark Norwood; Dominick Shaw; Sarah Lewis; Tessa Langley; Peter Thurley
Journal:  BMC Health Serv Res       Date:  2019-11-14       Impact factor: 2.655

5.  Impact of a statewide computed tomography scan educational campaign on radiation dose and repeat CT scan rates for transferred injured children.

Authors:  Rosemary Nabaweesi; Chary Akmyradov; Mary E Aitken; Phillip J Kenney; Raghu H Ramakrishnaiah
Journal:  J Clin Transl Sci       Date:  2021-05-24