Reproducibility of the water-drinking test in patients with exfoliation syndrome and exfoliative glaucoma.

Erhan Özyol1, Pelin Özyol2, Aylin Karalezli2.   

Abstract

PURPOSE: To evaluate the reproducibility of intraocular pressure (IOP) peaks and fluctuations detected during the water-drinking test (WDT) in patients with exfoliation syndrome (XFS) and exfoliative glaucoma (XFG).
METHODS: This prospective study included 34 XFS and 30 XFG patients. Each patient was evaluated twice, with the two WDTs performed on a 30-day interval. We recorded IOP peak (highest IOP during the WDT) and IOP fluctuation (IOP peak minus IOP before the test). Bland-Altman analysis was applied to assess the agreement of IOP peaks and fluctuations between the two consecutive visits. We defined reproducible as within 4 mmHg for IOP peak and within 2 mmHg for IOP fluctuation.
RESULTS: There were no significant differences in IOP values, IOP peaks and IOP fluctuations between the two visits for both XFS and XFG patients (p > 0.05, for all). The coefficient of repeatability for IOP peak was 2.5 mmHg and 3.5 mmHg in XFS and XFG patients respectively and for IOP fluctuation, it was 2.1 mmHg and 2.2 mmHg. None of the XFS or XFG patients had an IOP peak difference higher than 4 mmHg. Intraocular pressure (IOP) fluctuation differences above 2.0 mmHg were found in 8.8% of XFS patients and 16.6% of XFG patients.
CONCLUSIONS: Intraocular pressure (IOP) peak and IOP fluctuation have a reproducibility, both in XFS and in XFG.
© 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  exfoliation syndrome; exfoliative glaucoma; intraocular pressure; intraocular pressure fluctuation; water-drinking test

Mesh:

Substances:

Year:  2016        PMID: 27316559     DOI: 10.1111/aos.13132

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  2 in total

1.  Correlation between intraocular pressure obtained with water drinking test versus modified diurnal tension curve measurement in pseudoexfoliation glaucoma.

Authors:  Penpe Gül Firat; Seyhan Dikci; İlknur Tuncer Firat; Soner Demirel; Murat Firat; Emrah Öztürk; Zarife Ekici Gök
Journal:  Int Ophthalmol       Date:  2021-04-20       Impact factor: 2.031

Review 2.  Intraocular Pressure Changes after Water Drinking Test in Surgically Treated Primary Congenital Glaucoma.

Authors:  Reza Razeghinejad; Zahra Tajbakhsh; Masoumeh Beigom Masoumpour; M Hossein Nowroozzadeh
Journal:  J Ophthalmic Vis Res       Date:  2020-08-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.