Literature DB >> 2731536

Muscular fatigue during repeated isokinetic shoulder forward flexions in young females.

B Gerdle1, J Elert, K Henriksson-Larsén.   

Abstract

Peak torque, work, mean power and electromyographic (EMG) activity were recorded for each of 150 repeated isokinetic maximal shoulder flexions (45 degrees-90 degrees) in 23 healthy females. From the EMG signals of trapezius, deltoid, infraspinatus and biceps brachii the mean power frequency and the signal amplitude were determined in real time. The mechanical output showed a steep decrease during the first 40 contractions, followed by a plateau maintained until the end. In all muscles, except the biceps brachii, significant decreases in mean power frequency occurred during the first 40 contractions, showing a tendency to stabilize around the same absolute frequency value. Signal amplitude increased in the trapezius, the deltoid and the infraspinatus, but was constant in the biceps brachii. For some individuals rather high EMG activity was recorded in the muscles during the time the arm was supposed to be passively extended to the starting position, and this was found to be associated with lower strength and endurance levels. Longitudinal analyses showed that the mean power frequencies correlated better than the signal amplitudes with the three mechanical variables. The results suggest that the initial steep decrease in mechanical performance and mean power frequency is caused by fatiguing of type 2 motor units.

Entities:  

Mesh:

Year:  1989        PMID: 2731536     DOI: 10.1007/bf00418515

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  23 in total

1.  EMG: a non-invasive method for determination of fibre type proportion.

Authors:  M L Wretling; B Gerdle; K Henriksson-Larsén
Journal:  Acta Physiol Scand       Date:  1987-12

2.  Ankle angle effects on endurance time, median frequency and mean power of gastrocnemius EMG power spectrum: a comparison between individual and group analysis.

Authors:  P C Matthijsse; K M Hendrich; W H Rijnsburger; R D Woittiez; P A Huijing
Journal:  Ergonomics       Date:  1987-08       Impact factor: 2.778

3.  Factors determining the frequency content of the electromyogram.

Authors:  H Kranz; A M Williams; J Cassell; D J Caddy; R B Silberstein
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-08

4.  Relationship between myoelectric signals and blood lactate during incremental forearm exercise.

Authors:  T Moritani; H Tanaka; T Yoshida; C Ishii; T Yoshida; M Shindo
Journal:  Am J Phys Med       Date:  1984-06

5.  Characteristics of repeated isokinetic plantar flexions in middle-aged and elderly subjects with special regard to muscular work.

Authors:  A R Fugl-Meyer; B Gerdle; M Långström
Journal:  Acta Physiol Scand       Date:  1985-06

6.  Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts.

Authors:  B Bigland-Ritchie; E F Donovan; C S Roussos
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1981-11

7.  Myoelectric power spectrum dependence on muscular contraction level of elbow flexors.

Authors:  M Hagberg; B E Ericson
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1982

8.  Psychophysical bases of perceived exertion.

Authors:  G A Borg
Journal:  Med Sci Sports Exerc       Date:  1982       Impact factor: 5.411

9.  Effects of naloxone on dental pain threshold following muscle exercise and low frequency transcutaneous nerve stimulation: a comparative study in man.

Authors:  B Olausson; E Eriksson; L Ellmarker; B Rydenhag; B C Shyu; S A Andersson
Journal:  Acta Physiol Scand       Date:  1986-02

10.  Simultaneous measurement of muscle conduction velocity and EMG power spectrum changes during fatigue.

Authors:  A Eberstein; B Beattie
Journal:  Muscle Nerve       Date:  1985 Nov-Dec       Impact factor: 3.217

View more
  5 in total

1.  Effect of transcutaneous electrical acupoint stimulation on fatigue recovery of the quadriceps.

Authors:  Raymond C H So; Joseph K-F Ng; Gabriel Y F Ng
Journal:  Eur J Appl Physiol       Date:  2007-06-02       Impact factor: 3.078

2.  Quantification of the weakness and fatigue in thoracic outlet syndrome with isokinetic measurements.

Authors:  L Ozçakar; F Inanici; B Kaymak; G Abali; A Cetin; Z Hasçelik
Journal:  Br J Sports Med       Date:  2005-03       Impact factor: 13.800

3.  The relationship between contraction and relaxation during fatiguing isokinetic shoulder flexions. An electromyographic study.

Authors:  J Elert; B Gerdle
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

4.  Patterns of electromyographic shoulder muscle fatigue during MTM-paced repetitive arm work with and without pauses.

Authors:  G Sundelin
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

5.  The influence of acute hypoxic exposure on isokinetic muscle force production.

Authors:  Rafael Kenji Ivamoto; Fernanda Patti Nakamoto; Rodrigo Luiz Vancini; Ana Amélia Benedito-Silva; Claudio Andre Barbosa de Lira; Marília Dos Santos Andrade
Journal:  Springerplus       Date:  2014-10-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.