Differential effects of respiratory and electrical stimulation-induced dilator muscle contraction on mechanical properties of the pharynx in the pig.

A Brodsky1, Y Dotan2, M Samri3, A R Schwartz4, A Oliven5.   

Abstract

Respiratory stimulation (RS) during sleep often fails to discontinue flow limitation, whereas electrical stimulation (ES) of the hypoglossus (HG) nerve frequently prevents obstruction. The present work compares the effects of RS and HG-ES on pharyngeal mechanics and the relative contribution of tongue muscles and thoracic forces to pharyngeal patency. We determined the pressure-area relationship of the collapsible segment of the pharynx in anesthetized pigs under the following three conditions: baseline (BL), RS induced by partial obstruction of the tracheostomy tube, and HG-ES. Parameters were obtained also after transection of the neck muscles and the trachea (NMT) and after additional bilateral HG transection (HGT). In addition, we measured the force produced by in situ isolated geniohyoid (GH) during RS and HG-ES. Intense RS was recognized by large negative intrathoracic pressures and triggered high phasic genioglossus and GH EMG activity. GH contraction produced during maximal RS less than a quarter of the force obtained during HG-ES. The major finding of the study was that RS and ES differed in the mechanism by which they stabilized the pharynx: RS lowered the pressure-area slope, i.e., reduced pharyngeal compliance (14.1 ± 2.9 to 9.2 ± 1.9 mm(2)/cmH2O, P < 0.01). HG-ES shifted the slope toward lower pressures, i.e., lowered the calculated extraluminal pressure (17.4 ± 5.8 to 9.2 ± 7.4 cmH2O, P < 0.01). Changes during RS and HG-ES were not affected by NMT, but the effect of RS decreased significantly after HGT. In conclusion, HG-ES and RS affect the pharyngeal site of collapse differently. Tongue muscle contraction contributes to pharyngeal stiffening during RS.
Copyright © 2016 the American Physiological Society.

Entities:  

Keywords:  control of breathing; obstructive sleep apnea; respiratory stimulation; upper airway

Mesh:

Substances:

Year:  2016        PMID: 27311440     DOI: 10.1152/japplphysiol.00783.2015

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  2 in total

1.  Relationship between the activity of the genioglossus, other peri-pharyngeal muscles and flow mechanics during wakefulness and sleep in patients with OSA and healthy subjects.

Authors:  Ron Oliven; Guy Cohen; Mostafa Somri; Alan R Schwartz; Arie Oliven
Journal:  Respir Physiol Neurobiol       Date:  2019-12-19       Impact factor: 1.931

2.  Electrical stimulation of the whole hypoglossal nerve in patients with obstructive sleep apnea.

Authors:  A Oliven; Y Dotan; T Golibroda; M Somri; R Oliven; A R Schwartz
Journal:  Sleep Breath       Date:  2020-01-06       Impact factor: 2.655

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.