Surgical manipulation and the tensile strength of polypropylene sutures.

P B Dobrin1.   

Abstract

Laboratory studies were performed on 509 size 6-0 polypropylene sutures to examine the effects of surgical manipulation on suture tensile strength. Results showed that dragging sutures over the torn edge of the foil package, permanently kinking sutures, or axially twisting them up to four times did not decrease tensile strength. Similarly, the tug exerted by operating room nurses on polypropylene sutures did not decrease their tensile strength. Two manipulations, however, did decrease breaking strength. The presence of a stray knot reduced suture strength 17%, and grasping sutures with DeBakey forceps decreased suture strength in a dose-dependent fashion. When experienced surgeons grasped sutures with forceps out of direct vision, their grasping forces were well below that which alters tensile strength. Nevertheless, these results demonstrate that sutures that have acquired a stray knot should be discarded and that sutures should not be grasped with mechanical devices such as forceps.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2730316     DOI: 10.1001/archsurg.1989.01410060027005

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  5 in total

1.  Effects of temperature and strain level on stress relaxation behaviors of polypropylene sutures.

Authors:  Meng Deng; Jack Zhou
Journal:  J Mater Sci Mater Med       Date:  2006-04       Impact factor: 3.896

2.  Natural orifice surgery: initial US experience utilizing the StomaphyX device to reduce gastric pouches after Roux-en-Y gastric bypass.

Authors:  Dean Mikami; Bradley Needleman; Vimal Narula; Janice Durant; W Scott Melvin
Journal:  Surg Endosc       Date:  2009-07-25       Impact factor: 4.584

3.  A novel and efficient surgical knotting technique for high-tension closures.

Authors:  Yongyun Chang; Degang Yu; Liao Wang; Jingwei Zhang; Mengning Yan; Huiwu Li; Yuanqing Mao; Zanjing Zhai
Journal:  Ann Transl Med       Date:  2021-03

4.  Individualized Wound Closure-Mechanical Properties of Suture Materials.

Authors:  Elias Polykandriotis; Jonas Daenicke; Anil Bolat; Jasmin Grüner; Dirk W Schubert; Raymund E Horch
Journal:  J Pers Med       Date:  2022-06-25

5.  BioGlue® is not associated with polypropylene suture breakage after aortic surgery.

Authors:  Davide Pacini; Giacomo Murana; David Hollinworth; William F Northrup; Stacy G Arnold; Roberto Di Bartolomeo
Journal:  Front Surg       Date:  2022-09-09
  5 in total