Abstract

Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens for the detection of antibodies. Here, we compared the performance of the assay using non-magnetic beads with one based on the newly developed magnetic beads. We optimized the magnetic beads' coupling procedure and antibody detection assays for S. aureus and S. pneumoniae antigens and we measured IgG in human pooled serum against a series of S. aureus and S. pneumoniae-derived antigens in a singleplex and in a multiplex assay, respectively. For the multiplex assay, the comparison between magnetic and non-magnetic beads showed: i) in the majority of the cases (13 of the 17 tested S. pneumoniae antigens) significantly higher Median Fluorescence Intensity (MFI) values, ii) lower detection limits, iii) lower coefficient of variation (CV: 12% vs. 7% for non-magnetic vs. magnetic beads), so lower inter-assay variation and hence higher reproducibility. Magnetic bead coupling is cost effective, as we used 25% of the normal amount of antigen and only 50% of the beads in comparison to the non-magnetic beads. This optimized magnetic-based assay, which combines ease of use with an improved assay performance, allows detection of antibodies with a low titer that are potentially missed with the non-magnetic-based assay.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antigen coupling to magnetic beads; Bead-based assay; Microspheres; Staphylococcus aureus; Streptococcus pneumoniae

Mesh:

Substances:

Year:  2016        PMID: 27296810     DOI: 10.1016/j.jim.2016.06.003

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  4 in total

1.  Production of Staphylococcal Complement Inhibitor (SCIN) and Other Immune Modulators during the Early Stages of Staphylococcus aureus Biofilm Formation in a Mammalian Cell Culture Medium.

Authors:  Andi R Sultan; Jasper W Swierstra; Nicole A Lemmens-den Toom; Susan V Snijders; Silvie Hansenová Maňásková; Annelies Verbon; Willem J B van Wamel
Journal:  Infect Immun       Date:  2018-07-23       Impact factor: 3.441

2.  Alterations in metabolic biomarkers and their potential role in amyotrophic lateral sclerosis.

Authors:  Jin-Yue Li; Li-Ying Cui; Xiao-Han Sun; Dong-Chao Shen; Xun-Zhe Yang; Qing Liu; Ming-Sheng Liu
Journal:  Ann Clin Transl Neurol       Date:  2022-05-18       Impact factor: 5.430

3.  During the Early Stages of Staphylococcus aureus Biofilm Formation, Induced Neutrophil Extracellular Traps Are Degraded by Autologous Thermonuclease.

Authors:  Andi R Sultan; Tamara Hoppenbrouwers; Nicole A Lemmens-den Toom; Susan V Snijders; Johan W van Neck; Annelies Verbon; Moniek P M de Maat; Willem J B van Wamel
Journal:  Infect Immun       Date:  2019-11-18       Impact factor: 3.441

4.  A comparison of non-magnetic and magnetic beads for measuring IgG antibodies against Plasmodium vivax antigens in a multiplexed bead-based assay using Luminex technology (Bio-Plex 200 or MAGPIX).

Authors:  Ramin Mazhari; Jessica Brewster; Rich Fong; Caitlin Bourke; Zoe S J Liu; Eizo Takashima; Takafumi Tsuboi; Wai-Hong Tham; Matthias Harbers; Chetan Chitnis; Julie Healer; Maria Ome-Kaius; Jetsumon Sattabongkot; James Kazura; Leanne J Robinson; Christopher King; Ivo Mueller; Rhea J Longley
Journal:  PLoS One       Date:  2020-12-04       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.