Literature DB >> 27296204

Objective assessment of gait in xylazine-induced ataxic horses.

Y S Nout-Lomas1, K M Page2, H G Kang3, M E Aanstoos1, H M Greene2.   

Abstract

BACKGROUND: There is poor agreement between observers of equine neurological gait abnormalities using the modified Mayhew grading scale.
OBJECTIVES: To stimulate a dose-dependent ataxia in horses through xylazine administration and identify quantifiable relevant gait parameters. STUDY
DESIGN: Balanced, randomised, 2-way crossover design.
METHODS: Eight horses were assessed before and after administration of xylazine (low dose and high dose). Gait analyses performed before and after xylazine administration included: 1) kinematic data collected on an equine high-speed treadmill (flat and 10% decline) and from accelerometers placed on head and sacrum; and 2) kinetic data collected on a force plate.
RESULTS: All horses developed dose-dependent ataxia. Horses developed a dose-dependent increased stride time, stride length, and time of contact (P<0.0001), and a decreased stride frequency (P<0.0002) after administration of xylazine. Although pelvic acceleration increased in the mediolateral direction (P<0.05) in horses walked on the treadmill, this movement decreased when walking over ground after administration of xylazine (P<0.05). Furthermore, centre of pressure and path length indices changed significantly in horses following administration of xylazine (P<0.05). MAIN LIMITATIONS: This study examined one breed of horse (Arabian), all of similar height and weight. Accelerometers were attached to skin, not bone; no correction was made for artefacts from skin displacement. The sedative drug effect is of certain duration, limiting the data collection period.
CONCLUSIONS: Administration of xylazine induced a dose-dependent ataxia in horses and resulted in significant changes of gait parameters, pelvic accelerations, and stabilographic variables, some of which changed in a dose-dependent fashion. Some of the altered gait parameters in this model were probably a result of overall slowing down of the stride cycle secondary to the sedative effect. Continued efforts to discover and evaluate quantifiable gait parameters that are susceptible to change following development of clinical neurological disease in horses is warranted.
© 2016 EVJ Ltd.

Entities:  

Keywords:  accelerometer; force plate; horse; kinematic; kinetic; neurology; treadmill

Mesh:

Substances:

Year:  2016        PMID: 27296204     DOI: 10.1111/evj.12602

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  1 in total

1.  Outcomes after cervical vertebral interbody fusion using an interbody fusion device and polyaxial pedicle screw and rod construct in 10 horses (2015-2019).

Authors:  Lynn M Pezzanite; Jeremiah T Easley; Rosemary Bayless; Ellison Aldrich; Brad B Nelson; Howard B Seim; Yvette S Nout-Lomas
Journal:  Equine Vet J       Date:  2021-05-03       Impact factor: 2.692

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.