Literature DB >> 27294535

Gentamicin coating of plasma chemical oxidized titanium alloy prevents implant-related osteomyelitis in rats.

M Diefenbeck1, C Schrader2, F Gras3, T Mückley3, J Schmidt2, S Zankovych4, J Bossert4, K D Jandt5, A Völpel6, B W Sigusch6, H Schubert7, S Bischoff7, W Pfister8, B Edel8, M Faucon9, U Finger9.   

Abstract

Implant related infection is one of the most feared and devastating complication associated with the use of orthopaedic implant devices. Development of anti-infective surfaces is the main strategy to prevent implant contamination, biofilm formation and implant related osteomyelitis. A second concern in orthopaedics is insufficient osseointegration of uncemented implant devices. Recently, we reported on a macroporous titanium-oxide surface (bioactive TiOB) which increases osseointegration and implant fixation. To combine enhanced osseointegration and antibacterial function, the TiOB surfaces were, in addition, modified with a gentamicin coating. A rat osteomyelitis model with bilateral placement of titanium alloy implants was employed to analyse the prophylactic effect of gentamicin-sodiumdodecylsulfate (SDS) and gentamicin-tannic acid coatings in vivo. 20 rats were randomly assigned to four groups: (A) titanium alloy; PBS inoculum (negative control), (B) titanium alloy, Staphylococcus aureus inoculum (positive control), (C) bioactive TiOB with gentamicin-SDS and (D) bioactive TiOB plus gentamicin-tannic acid coating. Contamination of implants, bacterial load of bone powder and radiographic as well as histological signs of implant-related osteomyelitis were evaluated after four weeks. Gentamicin-SDS coating prevented implant contamination in 10 of 10 tibiae and gentamicin-tannic acid coating in 9 of 10 tibiae (infection prophylaxis rate 100% and 90% of cases, respectively). In Group (D) one implant showed colonisation of bacteria (swab of entry point and roll-out test positive for S. aureus). The interobserver reliability showed no difference in the histologic and radiographic osteomyelitis scores. In both gentamicin coated groups, a significant reduction of the histological osteomyelitis score (geometric mean values: C = 0.111 ± 0.023; D = 0.056 ± 0.006) compared to the positive control group (B: 0.244 ± 0.015; p < 0.05) was observed. The radiographic osteomyelitis scores confirmed these histological findings.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Animal model; Gentamicin coating; Implant-related infection; Plasma chemical oxidation; SDS; Tannic acid; Titanium alloys

Mesh:

Substances:

Year:  2016        PMID: 27294535     DOI: 10.1016/j.biomaterials.2016.05.039

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  22 in total

1.  CORR Insights®: Blended Chitosan Paste for Infection Prevention: Preliminary and Preclinical Evaluations.

Authors:  Ryan McLemore
Journal:  Clin Orthop Relat Res       Date:  2017-02-21       Impact factor: 4.176

Review 2.  Biomaterials against Bone Infection.

Authors:  María Vallet-Regí; Daniel Lozano; Blanca González; Isabel Izquierdo-Barba
Journal:  Adv Healthc Mater       Date:  2020-05-25       Impact factor: 9.933

Review 3.  Options and Limitations in Clinical Investigation of Bacterial Biofilms.

Authors:  Maria Magana; Christina Sereti; Anastasios Ioannidis; Courtney A Mitchell; Anthony R Ball; Emmanouil Magiorkinis; Stylianos Chatzipanagiotou; Michael R Hamblin; Maria Hadjifrangiskou; George P Tegos
Journal:  Clin Microbiol Rev       Date:  2018-04-04       Impact factor: 26.132

Review 4.  Staphylococcus aureus Evasion of Host Immunity in the Setting of Prosthetic Joint Infection: Biofilm and Beyond.

Authors:  Benjamin F Ricciardi; Gowrishankar Muthukrishnan; Elysia Masters; Mark Ninomiya; Charles C Lee; Edward M Schwarz
Journal:  Curr Rev Musculoskelet Med       Date:  2018-09

5.  Local and Systemic Changes Associated with Long-term, Percutaneous, Static Implantation of Titanium Alloys in Rhesus Macaques (Macaca mulatta).

Authors:  Galit H Frydman; Robert P Marini; Vasudevan Bakthavatchalu; Kathleen E Biddle; Sureshkumar Muthupalani; Charles R Vanderburg; Barry Lai; Pavan K Bendapudi; Ronald G Tompkins; James G Fox
Journal:  Comp Med       Date:  2017-03-01       Impact factor: 0.982

6.  A two-phase and long-lasting multi-antibacterial coating enables titanium biomaterials to prevent implants-related infections.

Authors:  Ruitian Lin; Zhuoran Wang; Zihan Li; Lisha Gu
Journal:  Mater Today Bio       Date:  2022-06-16

Review 7.  New developments and future challenges in prevention, diagnosis, and treatment of prosthetic joint infection.

Authors:  Benjamin F Ricciardi; Gowrishankar Muthukrishnan; Elysia A Masters; Nathan Kaplan; John L Daiss; Edward M Schwarz
Journal:  J Orthop Res       Date:  2020-01-31       Impact factor: 3.494

8.  Osteointegration, antimicrobial and antibiofilm activity of orthopaedic titanium surfaces coated with silver and strontium-doped hydroxyapatite using a novel blasting process.

Authors:  Caroline O' Sullivan; Liam O' Neill; Niall D O' Leary; James P O' Gara; Abina M Crean; Katie B Ryan
Journal:  Drug Deliv Transl Res       Date:  2021-03-13       Impact factor: 4.617

9.  Antimicrobial and enzyme-responsive multi-peptide surfaces for bone-anchored devices.

Authors:  Nicholas G Fischer; Xi Chen; Kristina Astleford-Hopper; Jiahe He; Alex F Mullikin; Kim C Mansky; Conrado Aparicio
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2021-04-16

10.  Is coating of titanium implants effective at preventing Staphylococcus aureus infections? A meta-analysis of animal model studies.

Authors:  Konstantinos Tsikopoulos; Konstantinos Sidiropoulos; Dimitrios Kitridis; Anas Hassan; Lorenzo Drago; Andreas Mavrogenis; Donald McBride
Journal:  Int Orthop       Date:  2020-08-06       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.