Non-invasive continuous arterial pressure and pulse pressure variation measured with Nexfin(®) in patients following major upper abdominal surgery: a comparative study.

R B P de Wilde1, F de Wit2, B F Geerts2, A L van Vliet2, L P H J Aarts2, J Vuyk2, J R C Jansen1.   

Abstract

We compared the accuracy and precision of the non-invasive Nexfin(®) device for determining systolic, diastolic, mean arterial pressure and pulse pressure variation, with arterial blood pressure values measured from a radial artery catheter in 19 patients following upper abdominal surgery. Measurements were taken at baseline and following fluid loading. Pooled data results of the arterial blood pressures showed no difference between the two measurement modalities. Bland-Altman analysis of pulse pressure variation showed significant differences between values obtained from the radial artery catheter and Nexfin finger cuff technology (mean (SD) 1.49 (2.09)%, p < 0.001, coefficient of variation 24%, limits of agreement -2.71% to 5.69%). The effect of volume expansion on pulse pressure variation was identical between methods (concordance correlation coefficient 0.848). We consider the Nexfin monitor system to be acceptable for use in patients after major upper abdominal surgery without major cardiovascular compromise or haemodynamic support.
© 2016 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Keywords:  arterial blood pressure; monitoring; pulse pressure variation

Mesh:

Year:  2016        PMID: 27291598     DOI: 10.1111/anae.13503

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  8 in total

1.  Continuous noninvasive monitoring of arterial pressure using the vascular unloading technique in comparison to the invasive gold standard in elderly comorbid patients: A prospective observational study.

Authors:  Phil Klose; Ulf Lorenzen; Rouven Berndt; Christoph Borzikowsky; Moritz Hill; Matthias Gruenewald; Gunnar Elke; Jochen Renner
Journal:  Health Sci Rep       Date:  2020-11-10

2.  A comparison of ClearSight noninvasive cardiac output and pulmonary artery bolus thermodilution cardiac output in cardiac surgery patients.

Authors:  Yuefu Wang; Weiqin Huang; Jiange Han; Yu Tian; Chunrong Wang; Lihuan Li
Journal:  Perioper Med (Lond)       Date:  2022-06-09

3.  Blood pressure measurement during cesarean delivery: Evaluation of a beat-to-beat noninvasive device (NexfinTM).

Authors:  Mathieu Bobet; Jona Joachim; Etienne Gayat; Agnès Bonnet; Kerstin Sievert; Carole Barnichon; Marc Fischler; Morgan Le Guen
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

4.  Pleth variability index or stroke volume optimization during open abdominal surgery: a randomized controlled trial.

Authors:  Hans Bahlmann; Robert G Hahn; Lena Nilsson
Journal:  BMC Anesthesiol       Date:  2018-08-18       Impact factor: 2.217

5.  Non-invasive measurement of pulse pressure variation using a finger-cuff method (CNAP system): a validation study in patients having neurosurgery.

Authors:  Moritz Flick; Phillip Hoppe; Jasmin Matin Mehr; Luisa Briesenick; Karim Kouz; Gillis Greiwe; Jürgen Fortin; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2021-02-25       Impact factor: 1.977

6.  Comparison of oscillometric, non-invasive and invasive arterial pressure monitoring in patients undergoing laparoscopic bariatric surgery - a secondary analysis of a prospective observational study.

Authors:  Ulf Lorenzen; Gunnar Elke; Jonathan Hansen; Markus Pohlmann; Jan H Beckmann; Phil Klose; Matthias Gruenewald; Jochen Renner
Journal:  BMC Anesthesiol       Date:  2022-03-28       Impact factor: 2.217

7.  Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery.

Authors:  Tadashi Tanioku; Akari Yoshida; Yuichi Aratani; Keisuke Fujii; Tomoyuki Kawamata
Journal:  BMC Anesthesiol       Date:  2020-07-20       Impact factor: 2.217

8.  Non-invasive measurement of pulse pressure variation using a finger-cuff method in obese patients having laparoscopic bariatric surgery.

Authors:  Moritz Flick; Roman Schumann; Phillip Hoppe; Iwona Bonney; Wilbert Wesselink; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2020-11-10       Impact factor: 1.977

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.