| Literature DB >> 27289247 |
E Jessica Ohashi Kurashige1, Shigeharu Oie2, H Furukawa1.
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) can contaminate environmental surfaces that are frequently touched by the hands of patients with MRSA colonization/infection. There have been many studies in which the presence or absence of MRSA contamination was determined but no studies in which MRSA contamination levels were also evaluated in detail. We evaluated MRSA contamination of environmental surfaces (overbed tables, bed side rails, and curtains) in the rooms of inpatients from whom MRSA was isolated via clinical specimens. We examined the curtains within 7-14 days after they had been newly hung. The environmental surfaces were wiped using gauze (molded gauze for wiping of surface bacteria; 100% cotton, 4cm×8cm) moistened with sterile physiological saline. The MRSA contamination rate and mean counts (range) were 25.0% (6/24 samples) and 30.6 (0-255)colony-forming units (cfu)/100cm(2), respectively, for the overbed tables and 31.6% (6/19 samples) and 159.5 (0-1620)cfu/100cm(2), respectively, for the bed side rails. No MRSA was detected in 24 curtain samples. The rate of MRSA contamination of environmental surfaces was high for the overbed tables and bed side rails but low for the curtains. Therefore, at least until the 14th day of use, frequent disinfection of curtains may be not necessary.Entities:
Keywords: Bed side rail; Contamination; Curtain; Methicillin-resistant Staphylococcus aureus; Overbed table
Mesh:
Year: 2016 PMID: 27289247 PMCID: PMC4927688 DOI: 10.1016/j.bjm.2016.04.002
Source DB: PubMed Journal: Braz J Microbiol ISSN: 1517-8382 Impact factor: 2.476
Methicillin-resistant Staphylococcus aureus (MRSA) contamination of the environmental surfaces in rooms of 24 inpatients with MRSA-positive body sites.
| Examined items (ca. 100 cm2) | Contaminant rate (%) (no. of samples/no. of samples examined) | Mean ± standard deviation (range) of the contamination level (cfu/examined item) |
|---|---|---|
| Overbed tables | 25.0 (6/24) | 30.6 ± 65.6 (0–255) |
| Bed side rails | 31.6 (6/19) | 159.5 ± 396.4 (0–1620) |
| Curtains | 0 (0/24) | 0 |
Nineteen samples were examined because beds without side rails were used in 5 of the 24 patients.