Superior mesenteric artery outcomes after fenestrated endovascular aortic aneurysm repair.

Salim Lala1, Martyn Knowles2, David Timaran3, Mirza Shadman Baig4, James Valentine5, Carlos Timaran3.   

Abstract

OBJECTIVE: The Zenith (Cook Medical, Bloomington, Ind) fenestrated endovascular graft may be designed with single-wide scallops or large fenestrations to address the superior mesenteric artery (SMA). Misalignment of the SMA with an unstented scallop or a large fenestration is possible. This study assessed SMA outcomes after fenestrated endovascular aortic aneurysm repair (FEVAR).
METHODS: During an 18-month period, 47 FEVARs were performed at a single institution. For analysis, patients were grouped according to unstented (n = 23) vs stented (n = 24) SMA scallops/fenestrations. The Institutional Review Board approved this single-institution observational study. Because this was a retrospective review of the data, patient consent was unnecessary for the study.
RESULTS: Technical success for FEVAR was 100%. The median follow-up period was 7.7 months (range, 1-16 months). Nine of 21 patients (43%) in the unstented group had some degree of misalignment of the SMA (range, 9%-71%). Among these, four patients (44%) developed complications: three SMA stenoses and one occlusion. The mean peak systolic velocity in patients with and without SMA misalignment was 317.8 cm/s vs 188.4 cm/s (P < .08), respectively. No misalignment occurred in the stented group, and only one of 19 patients (5%) developed an SMA stenosis that required angioplasty. Overall, patients with unstented SMAs had significantly more adverse events directly attributable to SMA misalignment than the stented group (44% vs 5%, respectively; P < .05).
CONCLUSIONS: Misalignment of the SMA with the use of unstented unreinforced scallops or fenestrations occurs frequently. Routine stenting of single-wide and large fenestrations, when feasible, may be a safer option for patients undergoing FEVAR.
Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27288103     DOI: 10.1016/j.jvs.2016.02.031

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  1 in total

1.  Balloon guidance for superior mesenteric artery scallop alignment during Cook Zenith Fenestrated AAA Endovascular Graft deployment.

Authors:  David P Kuwayama; Nikolaos Zacharias
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-06-25