Literature DB >> 27279933

Micro electrical impedance spectroscopy on a needle for ex vivo discrimination between human normal and cancer renal tissues.

Joho Yun1, Hyeon Woo Kim1, Yangkyu Park2, Jung-Joon Cha1, Jeong Zoo Lee3, Dong Gil Shin3, Jong-Hyun Lee.   

Abstract

The ex-vivo discrimination between human normal and cancer renal tissues was confirmed using μEoN (micro electrical impedance spectroscopy-on-a-needle) by measuring and comparing the electrical impedances in the frequency domain. To quantify the extent of discrimination between dissimilar tissues and to determine the optimal frequency at which the discrimination capability is at a maximum, discrimination index (DI) was employed for both magnitude and phase. The highest values of DI for the magnitude and phase were 5.15 at 1 MHz and 3.57 at 1 kHz, respectively. The mean magnitude and phase measured at the optimal frequency for normal tissues were 5013.40 ± 94.39 Ω and -68.54 ± 0.72°, respectively; those for cancer tissues were 4165.19 ± 70.32 Ω and -64.10 ± 0.52°, respectively. A statistically significant difference (p< 0.05) between the two tissues was observed at all the investigated frequencies. To extract the electrical properties (resistance and capacitance) of these bio-tissues through curve fitting with experimental results, an equivalent circuit was proposed based on the μEoN structure on the condition that the μEoN was immersed in the bio-tissues. The average and standard deviation of the extracted resistance and capacitance for the normal tissues were 6.22 ± 0.24 kΩ and 280.21 ± 32.25 pF, respectively, and those for the cancer tissues were 5.45 ± 0.22 kΩ and 376.32 ± 34.14 pF, respectively. The electrical impedance was higher in the normal tissues compared with the cancer tissues. The μEoN could clearly discriminate between normal and cancer tissues by comparing the results at the optimal frequency (magnitude and phase) and those of the curve fitting (extracted resistance and capacitance).

Entities:  

Year:  2016        PMID: 27279933      PMCID: PMC4874925          DOI: 10.1063/1.4951702

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  30 in total

1.  Linear and nonlinear electrode polarization and biological materials.

Authors:  H P Schwan
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

2.  Re: nephrectomy induced chronic renal insufficiency is associated with increased risk of cardiovascular death and death from any cause in patients with localized cT1b renal masses: C. J. Weight, B. T. Larson, A. F. Fergany, T. Gao, B. R. Lane, S. C. Campbell, J. H. Kaouk, E. A. Klein and A. C. Novick J Urol 2010; 183: 1317-1323.

Authors:  Nilay Patel; Mark Sullivan; David Cranston
Journal:  J Urol       Date:  2010-09-22       Impact factor: 7.450

3.  Electrochemical impedance spectroscopy to characterize inflammatory atherosclerotic plaques.

Authors:  Fei Yu; Xiaohu Dai; Tyler Beebe; Tzung Hsiai
Journal:  Biosens Bioelectron       Date:  2011-09-16       Impact factor: 10.618

4.  A microchip integrating cell array positioning with in situ single-cell impedance measurement.

Authors:  Xiaoliang Guo; Rong Zhu; Xianli Zong
Journal:  Analyst       Date:  2015-08-18       Impact factor: 4.616

5.  Reduction of electrode polarization capacitance in low-frequency impedance spectroscopy by using mesh electrodes.

Authors:  Divya Padmaraj; John H Miller; Jarek Wosik; Wanda Zagozdzon-Wosik
Journal:  Biosens Bioelectron       Date:  2011-07-30       Impact factor: 10.618

Review 6.  International variations and trends in renal cell carcinoma incidence and mortality.

Authors:  Ariana Znaor; Joannie Lortet-Tieulent; Mathieu Laversanne; Ahmedin Jemal; Freddie Bray
Journal:  Eur Urol       Date:  2014-10-16       Impact factor: 20.096

7.  Some early results related to electrical impedance of normal and abnormal gastric tissue.

Authors:  A Keshtkar; Z Salehnia; M H Somi; A T Eftekharsadat
Journal:  Phys Med       Date:  2011-02-22       Impact factor: 2.685

8.  Development of a noninvasive electrical impedance probe for minimally invasive tumor localization.

Authors:  Dai Yu; Du Jun; Yang Qing; Zhang Jianxun
Journal:  Physiol Meas       Date:  2015-08-03       Impact factor: 2.833

9.  Cancer incidence and mortality worldwide: sources, methods and major patterns in GLOBOCAN 2012.

Authors:  Jacques Ferlay; Isabelle Soerjomataram; Rajesh Dikshit; Sultan Eser; Colin Mathers; Marise Rebelo; Donald Maxwell Parkin; David Forman; Freddie Bray
Journal:  Int J Cancer       Date:  2014-10-09       Impact factor: 7.396

10.  Quantification of the specific membrane capacitance of single cells using a microfluidic device and impedance spectroscopy measurement.

Authors:  Qingyuan Tan; Graham A Ferrier; Brandon K Chen; Chen Wang; Yu Sun
Journal:  Biomicrofluidics       Date:  2012-08-13       Impact factor: 2.800

View more
  2 in total

1.  Fabrication of Fine Electrodes on the Tip of Hypodermic Needle Using Photoresist Spray Coating and Flexible Photomask for Biomedical Applications.

Authors:  Joho Yun; Jinhwan Kim; Jong-Hyun Lee
Journal:  J Vis Exp       Date:  2017-11-28       Impact factor: 1.355

Review 2.  The clinical application of electrical impedance technology in the detection of malignant neoplasms: a systematic review.

Authors:  Angela A Pathiraja; Ruwan A Weerakkody; Alexander C von Roon; Paul Ziprin; Richard Bayford
Journal:  J Transl Med       Date:  2020-06-08       Impact factor: 5.531

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.