Literature DB >> 27278539

Quantitative measurements of aortic valve coaptation by three-dimensional transesophageal echocardiography in patients with aortic regurgitation without primary leaflet disease.

Koichiro Imai1, Nozomi Watanabe2, Ken Saito2, Akihiro Hayashida2, Tomoko Maehama2, Yoshinori Miyamoto2, Takahiro Kawamoto2, Yoji Neishi2, Hiroyuki Okura2, Kiyoshi Yoshida2.   

Abstract

BACKGROUND: Aortic regurgitation (AR) without primary leaflet disease (functional AR) is known to occur as a result of loss of coaptation due to sinotubular junction (STJ) dilatation. However, the characteristics of change in the aortic valve coaptation length (AVCL) in 3 cusps in patients with functional AR are, as yet, unclear. The aim of this study was to measure the AVCL in 3 cusps in patients with functional AR by three-dimensional transesophageal echocardiograph (3D TEE). METHODS AND
RESULTS: Thirteen patients with functional AR with or without aortic dilatation (trivial to mild AR [group A] and moderate to severe AR [group B]) and 7 controls without AR (group N) were examined. We measured the AVCL between the left coronary cusp (LCC) and right coronary cusp (RCC), the LCC and non coronary cusp (NCC), the RCC and NCC, and we also measured the cusp projection area, STJ arc length, leaflet tip-Valsalva wall distance and inter-commissural distance in each cusp by 3D TEE. The average AVCL was significantly shorter in group B than in groups N and A (P < 0.001). Particularly, in group B, there was a significant difference in AVCL in the 3 cusps (P = 0.043). Moreover, although there were no significant differences in the size of cusps in groups N and A, there was disproportion in the size of those cusps in group B with the largest in RCC.
CONCLUSION: Cusp enlargement was not uniform and was greatest in the RCC, and the loss of coaptation between the 3 cusps was also not uniform, with predominant reduction in the coaptation between the RCC and the other 2 cusps.

Entities:  

Keywords:  Aortic valve coaptation; Functional aortic regurgitation; Three-dimensional echocardiography

Year:  2009        PMID: 27278539     DOI: 10.1007/s12574-009-0028-y

Source DB:  PubMed          Journal:  J Echocardiogr        ISSN: 1349-0222


  22 in total

1.  New three-dimensional echocardiographic system using digital radiofrequency data--visualization and quantitative analysis of aortic valve dynamics with high resolution: methods, feasibility, and initial clinical experience.

Authors:  Michael Handke; Cosima Jahnke; Gudrun Heinrichs; Jörg Schlegel; Clemens Vos; Daniel Schmitt; Christoph Bode; Annette Geibel
Journal:  Circulation       Date:  2003-06-02       Impact factor: 29.690

2.  Mitral annulus flattens in ischemic mitral regurgitation: geometric differences between inferior and anterior myocardial infarction: a real-time 3-dimensional echocardiographic study.

Authors:  Nozomi Watanabe; Yasuo Ogasawara; Yasuko Yamaura; Nozomi Wada; Takahiro Kawamoto; Eiji Toyota; Takashi Akasaka; Kiyoshi Yoshida
Journal:  Circulation       Date:  2005-08-30       Impact factor: 29.690

3.  Esophageal echocardiography.

Authors:  L Frazin; J V Talano; L Stephanides; H S Loeb; L Kopel; R M Gunnar
Journal:  Circulation       Date:  1976-07       Impact factor: 29.690

4.  Dimensions and geometric relationships of the human aortic valve as a function of pressure.

Authors:  M Swanson; R E Clark
Journal:  Circ Res       Date:  1974-12       Impact factor: 17.367

5.  Mechanism of valvular incompetence in aortic sinus dilatation.

Authors:  B J Bellhouse; F Bellhouse; J A Abbott; L Talbot
Journal:  Cardiovasc Res       Date:  1973-07       Impact factor: 10.787

6.  Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations.

Authors:  P M Vandervoort; J M Rivera; D Mele; I F Palacios; R E Dinsmore; A E Weyman; R A Levine; J D Thomas
Journal:  Circulation       Date:  1993-09       Impact factor: 29.690

7.  Morphological analysis of aortic root in eccentric aortic regurgitation using anyplane two-dimensional images produced by transesophageal three-dimensional echocardiography.

Authors:  Yoshihiro Sato; Junya Kamata; Hiroshi Izumoto; Masataka Nasu; Kohei Kawazoe
Journal:  J Heart Valve Dis       Date:  2003-03

8.  Prevalence of aortic regurgitation by color flow Doppler in relation to aortic root size.

Authors:  J D Seder; J F Burke; F J Pauletto
Journal:  J Am Soc Echocardiogr       Date:  1990 Jul-Aug       Impact factor: 5.251

9.  Two-dimensional echocardiographic assessment of the progression of aortic root size in 127 patients with chronic aortic regurgitation: role of the supraaortic ridge and relation to the progression of the lesion.

Authors:  L R Padial; A Oliver; A Sagie; A E Weyman; M E King; R A Levine
Journal:  Am Heart J       Date:  1997-11       Impact factor: 4.749

10.  Is repair of aortic valve regurgitation a safe alternative to valve replacement?

Authors:  Kenji Minakata; Hartzell V Schaff; Kenton J Zehr; Joseph A Dearani; Richard C Daly; Thomas A Orszulak; Francisco J Puga; Gordon K Danielson
Journal:  J Thorac Cardiovasc Surg       Date:  2004-03       Impact factor: 5.209

View more
  1 in total

1.  Usefulness of real-time three-dimensional echocardiography in evaluating aortic root diameters during a cardiac cycle.

Authors:  Chisato Izumi; Makoto Miyake; Shuichi Takahashi; Hidetaka Hayashi; Tadashi Miyanishi; Hayato Matsutani; Sumiyo Hashiwada; Kazuyo Kuwano; Jiro Sakamoto; Yoshihisa Nakagawa
Journal:  J Echocardiogr       Date:  2012-01-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.