Literature DB >> 27278017

Three-dimensional visualisation of soft biological structures by X-ray computed micro-tomography.

Tom Shearer1, Robert S Bradley2, L Araida Hidalgo-Bastida3, Michael J Sherratt4, Sarah H Cartmell5.   

Abstract

Whereas the two-dimensional (2D) visualisation of biological samples is routine, three-dimensional (3D) imaging remains a time-consuming and relatively specialised pursuit. Current commonly adopted techniques for characterising the 3D structure of non-calcified tissues and biomaterials include optical and electron microscopy of serial sections and sectioned block faces, and the visualisation of intact samples by confocal microscopy or electron tomography. As an alternative to these approaches, X-ray computed micro-tomography (microCT) can both rapidly image the internal 3D structure of macroscopic volumes at sub-micron resolutions and visualise dynamic changes in living tissues at a microsecond scale. In this Commentary, we discuss the history and current capabilities of microCT. To that end, we present four case studies to illustrate the ability of microCT to visualise and quantify: (1) pressure-induced changes in the internal structure of unstained rat arteries, (2) the differential morphology of stained collagen fascicles in tendon and ligament, (3) the development of Vanessa cardui chrysalises, and (4) the distribution of cells within a tissue-engineering construct. Future developments in detector design and the use of synchrotron X-ray sources might enable real-time 3D imaging of dynamically remodelling biological samples.
© 2016. Published by The Company of Biologists Ltd.

Entities:  

Keywords:  Arteries; MicroCT; Tendon; Tissue engineering; Tomography; X-ray

Mesh:

Substances:

Year:  2016        PMID: 27278017     DOI: 10.1242/jcs.179077

Source DB:  PubMed          Journal:  J Cell Sci        ISSN: 0021-9533            Impact factor:   5.285


  19 in total

1.  Reciprocal Spatiotemporally Controlled Apoptosis Regulates Wolffian Duct Cloaca Fusion.

Authors:  Masato Hoshi; Antoine Reginensi; Matthew S Joens; James A J Fitzpatrick; Helen McNeill; Sanjay Jain
Journal:  J Am Soc Nephrol       Date:  2018-01-11       Impact factor: 10.121

2.  Synchrotron X-ray biosample imaging: opportunities and challenges.

Authors:  Gabriela Sena; Gabriel Fidalgo; Katrine Paiva; Renan Barcelos; Liebert Parreiras Nogueira; Marcos Vinícius Colaço; Marcelo Salabert Gonzalez; Patricia Azambuja; Gustavo Colaço; Helio Ricardo da Silva; Anderson Alvarenga de Moura Meneses; Regina Cély Barroso
Journal:  Biophys Rev       Date:  2022-06-02

3.  Differentiation of benign and malignant regions in paraffin embedded tissue blocks of pulmonary adenocarcinoma using micro CT scanning of paraffin tissue blocks: a pilot study for method validation.

Authors:  Ayten Kayı Cangır; Serpil Dizbay Sak; Gökalp Güneş; Kaan Orhan
Journal:  Surg Today       Date:  2021-03-01       Impact factor: 2.549

4.  p21-/- Mice Exhibit Spontaneous Articular Cartilage Regeneration Post-Injury.

Authors:  Christina L Jablonski; Bryce A Besler; Jahaan Ali; Roman J Krawetz
Journal:  Cartilage       Date:  2019-09-26       Impact factor: 3.117

5.  The relative compliance of energy-storing tendons may be due to the helical fibril arrangement of their fascicles.

Authors:  Tom Shearer; Chavaunne T Thorpe; Hazel R C Screen
Journal:  J R Soc Interface       Date:  2017-08       Impact factor: 4.118

6.  Multi-scale X-ray computed tomography to detect and localize metal-based nanomaterials in lung tissues of in vivo exposed mice.

Authors:  Perrine Chaurand; Wei Liu; Daniel Borschneck; Clément Levard; Mélanie Auffan; Emmanuel Paul; Blanche Collin; Isabelle Kieffer; Sophie Lanone; Jérôme Rose; Jeanne Perrin
Journal:  Sci Rep       Date:  2018-03-13       Impact factor: 4.379

7.  * Microcomputed Tomography Technique for In Vivo Three-Dimensional Fat Tissue Volume Evaluation After Polymer Injection.

Authors:  Sarah Berndt; Ioana Konz; Didier Colin; Stéphane Germain; Brigitte Pittet-Cuénod; Harm-Anton Klok; Ali Modarressi
Journal:  Tissue Eng Part C Methods       Date:  2017-10-03       Impact factor: 3.056

Review 8.  X-ray Micro-Computed Tomography: An Emerging Technology to Analyze Vascular Calcification in Animal Models.

Authors:  Samantha J Borland; Julia Behnsen; Nick Ashton; Sheila E Francis; Keith Brennan; Michael J Sherratt; Philip J Withers; Ann E Canfield
Journal:  Int J Mol Sci       Date:  2020-06-25       Impact factor: 5.923

9.  A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging.

Authors:  Charlotte K Hagen; Marco Endrizzi; Rebecca Towns; Jeffrey A Meganck; Alessandro Olivo
Journal:  Mol Imaging Biol       Date:  2020-06       Impact factor: 3.488

10.  Imaging the mammary gland and mammary tumours in 3D: optical tissue clearing and immunofluorescence methods.

Authors:  Bethan Lloyd-Lewis; Felicity M Davis; Olivia B Harris; Jessica R Hitchcock; Filipe C Lourenco; Mathias Pasche; Christine J Watson
Journal:  Breast Cancer Res       Date:  2016-12-13       Impact factor: 6.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.