Literature DB >> 27277906

Reproducibility of two different methods for performing mean gray value evaluation of cyst content in endometriomas using VOCAL.

Stefano Guerriero1, Juan Luis Alcazar2, Monica Pilloni3, Silvia Ajossa3, Begoña Olartecoechea2, Federica Sedda3, Alba Piras3, Gian Benedetto Melis3, Luca Saba4.   

Abstract

OBJECTIVE: To compare two different methods (manual sampling of the entire cyst and semi-automated spherical sampling from the central part of the cyst) for calculating the mean gray value (MGV) from the cystic content in endometriomas using virtual organ computer-aided analysis (VOCAL).
METHODS: Forty-one volumes from histologically confirmed endometriomas were retrieved from our database and the volumes were analyzed to compare the MGVs obtained via the two modalities. In addition, to evaluate the reproducibility in a sample of 20 volumes, two different observers calculated the MGV from cyst content using VOCAL software. For each method, each examiner analyzed the volumes twice, 3 weeks apart, for assessment of intra-observer agreement. First, manual sampling of the internal contour of all the cysts was performed, and 1 week later semi-automated 2-cm sphere sampling from the central part of the cyst was carried out. In addition, the observers recorded the time spent performing each analysis. Inter- and intra-observer reproducibility was evaluated for each method using intra-class correlation coefficients (ICC).
RESULTS: There was no difference in the mean MGV between manual sampling (22.211 ± 7.541) and the semi-automated modality of sampling (23.840 ± 8.621, p = 0.439). The correlation between manual and semi-automated sampling measurement was high (r = 0.92). According to the ICCs, there was no significant difference in interobserver reliability between manual sampling (0.931; 95 % CI, 0.824-0.973) and the semi-automated modality of sampling (0.924; 95 % CI, 0.809-0.970). Intra-observer reproducibility for both examiners was good (ICC > 0.94). Semi-automated measurements were obtained faster than those obtained by manual evaluation (p = 0.0001 for observer 1 and p = 0.083 for observer 2).
CONCLUSIONS: Both methods seem to be reliable, but the semi-automated method using the sphere should be preferred because it is a less time-consuming procedure.

Entities:  

Keywords:  3D power Doppler ultrasound; Endometrioma; Interobserver variability; Intra-observer variability; Mean gray value; VOCAL

Mesh:

Year:  2013        PMID: 27277906     DOI: 10.1007/s10396-013-0514-8

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  19 in total

1.  Assessment of fetal lung development by quantitative ultrasonic tissue characterization: a methodical study.

Authors:  Ismail Tekesin; Georgia Anderer; Lars Hellmeyer; Werner Stein; Maritta Kühnert; Stephan Schmidt
Journal:  Prenat Diagn       Date:  2004-09       Impact factor: 3.050

2.  A three-dimensional ultrasonographic quantitative analysis of non-ulcerated carotid plaque morphology in symptomatic and asymptomatic carotid stenosis.

Authors:  John Heliopoulos; Konstantinos Vadikolias; Panayiotis Mitsias; Dimitrios Artemis; Grigorios Tripsianis; Charitomeni Piperidou; Nicolaos Artemis
Journal:  Atherosclerosis       Date:  2008-01-24       Impact factor: 5.162

Review 3.  Clinical practice. Endometriosis.

Authors:  Linda C Giudice
Journal:  N Engl J Med       Date:  2010-06-24       Impact factor: 91.245

4.  Mean grey value is lower in endometriomas: differentiating a hypoechogenic adnexal cyst by 3-dimensional power Doppler ultrasound--a preliminary study.

Authors:  Chen-Yu Huang; Hsing-I Wang; Peng-Hui Wang; Yi-Cheng Wu; Ming-Jie Yang; Li-Hsun Chen; Kuan-Chong Chao; Chih-Yao Chen
Journal:  J Chin Med Assoc       Date:  2011-02-12       Impact factor: 2.743

5.  The efficiency of transvaginal ultrasonography in the diagnosis of endometrioma.

Authors:  V Mais; S Guerriero; S Ajossa; M Angiolucci; A M Paoletti; G B Melis
Journal:  Fertil Steril       Date:  1993-11       Impact factor: 7.329

Review 6.  Characterising acute gynaecological pathology with ultrasound: an overview and case examples.

Authors:  Lil Valentin
Journal:  Best Pract Res Clin Obstet Gynaecol       Date:  2009-04-28       Impact factor: 5.237

7.  Tissue characterization using mean gray value analysis in deep infiltrating endometriosis.

Authors:  S Guerriero; M Pilloni; J L Alcazar; F Sedda; S Ajossa; V Mais; G B Melis; L Saba
Journal:  Ultrasound Obstet Gynecol       Date:  2013-04       Impact factor: 7.299

Review 8.  A systematic review of the accuracy of ultrasound in the diagnosis of endometriosis.

Authors:  J Moore; S Copley; J Morris; D Lindsell; S Golding; S Kennedy
Journal:  Ultrasound Obstet Gynecol       Date:  2002-12       Impact factor: 7.299

9.  Assessment of cyst content using mean gray value for discriminating endometrioma from other unilocular cysts in premenopausal women.

Authors:  J L Alcázar; M León; R Galván; S Guerriero
Journal:  Ultrasound Obstet Gynecol       Date:  2010-02       Impact factor: 7.299

10.  Evaluation of two different methods for vascular sampling by three-dimensional power Doppler angiography in solid and cystic-solid adnexal masses.

Authors:  J L Alcázar; M Prka
Journal:  Ultrasound Obstet Gynecol       Date:  2009-03       Impact factor: 7.299

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.