Literature DB >> 27277459

Ultrasound evaluation of elbow fractures in children.

Kolja Eckert1, Ole Ackermann2, Bernd Schweiger3, Elke Radeloff4, Peter Liedgens4.   

Abstract

PURPOSE: Elbow fractures are a common pathology in any pediatric emergency unit. X-ray of the elbow is the standard diagnostic procedure. Previous studies have shown that fractures can also be visualized by ultrasound (US). The aim of our study was to evaluate the diagnostic accuracy of US in comparison to X-rays in diagnosing pediatric elbow fractures.
METHODS: Sixty-seven patients aged 1-13 years with clinically suspected elbow fracture were first examined by US followed by standard two-plane radiographs. US examination was done with a 12-MHz linear probe from seven longitudinal positions across the distal humerus and additionally from longitudinal positions across the radial head and olecranon. The sonographic and radiological findings were compared in a contingency table, and sensitivity, specificity, and positive and negative predictive values of the US diagnostic procedure were calculated.
RESULTS: With X-ray, we found 48 patients with an elbow fracture and 19 patients with no fracture. With US, we found 46 patients with an elbow fracture and 21 patients with no fracture. In comparison to X-ray diagnosis, we calculated for US diagnosis a sensitivity of 97.9 %, a specificity of 95 %, a negative predictive value of 95 %, and a positive predictive value of 97.9 %.
CONCLUSION: Typical elbow fractures in children could also be visualized by US. A positive fat pad sign, in particular, serves as a strong indicator for elbow joint fractures and can be identified very sensitively by US. We confirm US as a valuable primary screening tool for elbow injuries in children. In the absence of US signs of fracture and in sonographically confirmed non-displaced fractures, standard X-rays are dispensable, thereby minimizing the X-ray burden in children without loss of diagnostic safety.

Entities:  

Keywords:  Children; Elbow; Supracondylar fracture; Ultrasound

Year:  2013        PMID: 27277459     DOI: 10.1007/s10396-013-0446-3

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  31 in total

Review 1.  Ultrasound of the elbow.

Authors:  C Martinoli; S Bianchi; M P Zamorani; J L Zunzunegui; L E Derchi
Journal:  Eur J Ultrasound       Date:  2001-10

2.  Roentgenologic visualization of the extracapsular fat; its importance in the diagnosis of traumatic injuries to the elbow.

Authors:  H G NORELL
Journal:  Acta radiol       Date:  1954-09       Impact factor: 1.990

3.  [Radiographic examination of injuries in children. Clinical and legal considerations about indications].

Authors:  G Alzen; D Duque-Reina; R Urhahn; G Solbach
Journal:  Dtsch Med Wochenschr       Date:  1992-03-06       Impact factor: 0.628

4.  Sonography of the normal elbow.

Authors:  L L Barr; D S Babcock
Journal:  AJR Am J Roentgenol       Date:  1991-10       Impact factor: 3.959

5.  [Possibilities for using sonography as a diagnostic procedure in fractures during the growth period].

Authors:  F J Rathfelder; O Paar
Journal:  Unfallchirurg       Date:  1995-12       Impact factor: 1.000

6.  [Ultrasound diagnosis of forearm fractures in children: a prospective multicenter study].

Authors:  O Ackermann; P Liedgens; K Eckert; E Chelangattucherry; B Husain; S Ruchholtz
Journal:  Unfallchirurg       Date:  2009-08       Impact factor: 1.000

7.  [Sonographic diagnosis of supracondylar fractures of the humerus].

Authors:  G Pistor; H Graffstädt
Journal:  Ultraschall Med       Date:  2003-10       Impact factor: 6.548

8.  Acute elbow trauma in children: role of ultrasonography.

Authors:  Iñaki Zuazo; Olivier Bonnefoy; Catherine Tauzin; Antoine Borocco; Alain Lippa; Mathieu Legrand; Jean-François Chateil
Journal:  Pediatr Radiol       Date:  2008-07-15

9.  Ultrasound in diagnosis of fractures in children: unnecessary harassment or useful addition to X-ray?

Authors:  J D Moritz; L D Berthold; S F Soenksen; G F Alzen
Journal:  Ultraschall Med       Date:  2008-06       Impact factor: 6.548

10.  Ultrasonographic evaluation of the elbow in infants and young children after suspected trauma.

Authors:  R S Davidson; R I Markowitz; J Dormans; D S Drummond
Journal:  J Bone Joint Surg Am       Date:  1994-12       Impact factor: 5.284

View more
  7 in total

1.  Accuracy of the sonographic fat pad sign for primary screening of pediatric elbow fractures: a preliminary study.

Authors:  Kolja Eckert; Ole Ackermann; Niklas Janssen; Bernd Schweiger; Elke Radeloff; Peter Liedgens
Journal:  J Med Ultrason (2001)       Date:  2014-03-06       Impact factor: 1.314

Review 2.  [Sonographic fracture diagnostics].

Authors:  K Eckert; O Ackermann
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

3.  The Investigation of Suspected Fracture-a Comparison of Ultrasound With Conventional Imaging.

Authors:  Gordian Lukas Schmid; Stefan Lippmann; Susanne Unverzagt; Christiane Hofmann; Tobias Deutsch; Thomas Frese
Journal:  Dtsch Arztebl Int       Date:  2017-11-10       Impact factor: 5.594

4.  [Sonographic fracture diagnosis in children].

Authors:  K Eckert; O Ackermann
Journal:  Unfallchirurg       Date:  2014-04       Impact factor: 1.000

5.  Bedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CT-Comparative Diagnostic Study.

Authors:  Michael-Alexander Malahias; Philip-Panagiotis Manolopoulos; Vikram Kadu; Omid Shahpari; Dimitrios Fagkrezos; Maria-Kyriaki Kaseta
Journal:  Arch Bone Jt Surg       Date:  2018-11

6.  Transverse and Oblique Long Bone Fracture Evaluation by Low Order Ultrasonic Guided Waves: A Simulation Study.

Authors:  Ying Li; Dan Liu; Kailiang Xu; Dean Ta; Lawrence H Le; Weiqi Wang
Journal:  Biomed Res Int       Date:  2017-01-15       Impact factor: 3.411

7.  Ultrasonography-guided closed reduction in the treatment of displaced transphyseal fracture of the distal humerus.

Authors:  Hai Zhou; Ge Zhang; Ming Li; Xiangyang Qu; Yujiang Cao; Xing Liu; Yuan Zhang
Journal:  J Orthop Surg Res       Date:  2020-12-01       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.