Literature DB >> 27276200

Value and Efficacy of Sentinel Lymph Node Diagnostics in Patients With Penile Carcinoma With Nonpalpable Inguinal Lymph Nodes: Five-Year Follow-up.

Ulf Lützen1, Maaz Zuhayra, Marlies Marx, Yi Zhao, Stephanie Knüpfer, Christian Colberg, Klaus-Peter Jünemann, Carsten Maik Naumann.   

Abstract

PURPOSE: Sentinel lymph node biopsy (SLNB) has been described as a minimally invasive method for lymph node staging in patients with a penile carcinoma and nonpalpable inguinal nodes in national and international guidelines of involved professional societies. However, this method is rarely used. The aim of this study was to validate reliability and morbidity of this method and to discuss radiation exposure of persons involved.
METHODS: Twenty-eight patients with histologically negative sentinel lymph nodes in 47 groins with nonpalpable inguinal lymph nodes were included in this study (17 T1(a/b)-, 8 T2- and 3 T3-stages). We recorded prospectively all cases of lymph node recurrence and complications in patients with initially nonpalpable inguinal lymph nodes and histologically negative sentinel lymph nodes. False-negative findings and morbidity were calculated as qualitative criteria. Inguinal regions with palpable lymph nodes and/or evidence of metastases were not considered in accordance with the guidelines.
RESULTS: During a median follow-up of 68 (4-131) months, we observed one case of bilateral lymph node recurrence and one case of prolonged inguinal lymphorrhea, which could be managed conservatively. Per inguinal region, false-negative rate was 4.25%, and morbidity rate was 2.12%; seen per patient, the rates were both 3.57%.
CONCLUSIONS: Sentinel lymph node biopsy under use of radioactive tracers is a reliable method of lymph node staging in patients with penile carcinoma and nonpalpable inguinal lymph nodes. The methodical complexity is justified by high reliability and low radiation exposure for both patient and medical staff and low morbidity rates.

Entities:  

Mesh:

Year:  2016        PMID: 27276200     DOI: 10.1097/RLU.0000000000001268

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  4 in total

1.  Anatomical localization of radiocolloid tracer deposition affects outcome of sentinel node procedures in prostate cancer.

Authors:  C M de Korne; E M Wit; J de Jong; R A Valdés Olmos; T Buckle; F W B van Leeuwen; H G van der Poel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-08-03       Impact factor: 9.236

2.  Diagnostic precision of sentinel lymph node biopsy in penile cancer.

Authors:  Jose Gustavo Ramos; David Camilo Jaramillo; David Sandoval; Laura Juliana Gallego; Carlos Riveros; Jonathan Armando Sierra; Isis Vargas; Byron Eduardo López De Mesa López; Linda Ibata; Rodolfo Varela
Journal:  Indian J Urol       Date:  2019 Oct-Dec

3.  Histological subtype is a significant predictor for inguinal lymph node metastasis in patients with penile squamous cell carcinoma.

Authors:  Jin-You Wang; Ming-Zhu Gao; De-Xin Yu; Dong-Dong Xie; Yi Wang; Liang-Kuan Bi; Tao Zhang; De-Mao Ding
Journal:  Asian J Androl       Date:  2018 May-Jun       Impact factor: 3.285

4.  Clinical application of carbon nanoparticles in curative resection for colorectal carcinoma.

Authors:  Li-Yu Wang; Jia-Huan Li; Xing Zhou; Qi-Chang Zheng; Xiang Cheng
Journal:  Onco Targets Ther       Date:  2017-11-22       Impact factor: 4.147

  4 in total