Spinal anesthesia and direction of spinal needle bevel.

Smita Prakash1, Parul Mullick1.   

Abstract

Entities:  

Year:  2016        PMID: 27275065      PMCID: PMC4874090          DOI: 10.4103/0970-9185.173360

Source DB:  PubMed          Journal:  J Anaesthesiol Clin Pharmacol        ISSN: 0970-9185


× No keyword cloud information.
Sir, We read with interest the article “Subarachnoid space needle manipulations for a successful block”[1] that prompted us to mention another misguided needle manipulation with regard to Quincke spinal needle. Of the several factors that determine the spread of local anesthetic (LA) solutions in the cerebrospinal fluid (CSF), the direction in which the bevel of the lumbar puncture needle faces is one such factor. It is not uncommon to observe resident anesthesiologists performing the subarachnoid block to rotate the spinal needle (after obtaining CSF flow) such that the bevel faces cephalad. The purpose of the rotation is to direct the LA stream cephalad for greater spread. However, the direction in which the bevel of a Quincke needle (often used in our setup) faces does not influence the distribution of LA solution in CSF.[2] The terminal lumen of Quincke needle lies in the same axis as the lumen of the shaft of the needle. A liquid injected through such a needle exits from the needle in the same straight line formed by the lumen of the needle throughout its length.[3] This can be easily demonstrated by injecting any solution in the air through a Quincke needle. It will be observed that the exit stream goes in the same straight line regardless of the direction in which the bevel faces. In contrast, the orientation of the orifice of Whitacre or Tuohy needle influences the direction in which an injected solution exits from the needle; the exit stream leaves at an angle of 55° to the Whitacre needle plane[4] and at a 45° angle with Tuohy needle.[3] Thus, orifice direction of both these needles affects the distribution of LA solution in the CSF. In conclusion, during performance of a subarachnoid block the bevel of a Quincke needle may be rotated to obtain an improved flow of CSF or to ensure that CSF flow is obtained with the bevel in each of the four directions, but not with the view to influence the direction of exit of LA solution.
  4 in total

1.  Hyperbaric dye solution distribution characteristics after pencil-point needle injection in a spinal cord model.

Authors:  S J Holman; R A Robinson; D Beardsley; S F Stewart; L Klein; R A Stevens
Journal:  Anesthesiology       Date:  1997-04       Impact factor: 7.892

2.  Effects of speed and direction of injection on the level and duration of spinal anesthesia.

Authors:  J L Neigh; P B Kane; T C Smith
Journal:  Anesth Analg       Date:  1970 Nov-Dec       Impact factor: 5.108

Review 3.  Distribution of local anesthetic solutions within the subarachnoid space.

Authors:  N M Greene
Journal:  Anesth Analg       Date:  1985-07       Impact factor: 5.108

4.  Subarachnoid space needle manipulations for successful block.

Authors:  Deepak Gupta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-07
  4 in total
  1 in total

1.  Subarachnoid space needle's eyelet in dural-arachnoid side-wall of lumbar cistern: Whitacre vs. Quincke.

Authors:  Deepak Gupta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Oct-Dec
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.