Dual-Energy CT of Rectal Cancer Specimens: A CT-based Method for Mesorectal Lymph Node Characterization.

Issam Al-Najami1, Regina G H Beets-Tan, Gunvor Madsen, Gunnar Baatrup.   

Abstract

BACKGROUND: An accurate method to assess malignant lymph nodes in the mesorectum is needed. Dual-energy CT scans simultaneously with 2 levels of energy and thereby provides information about tissue composition based on the known effective Z value of different tissues. Each point investigated is represented by a certain effective Z value, which allows for information on its composition.
OBJECTIVE: We wanted to standardize a method for dual-energy scanning of rectal specimens to evaluate the sensitivity and specificity of benign versus malignant lymph node differentiation. Histopathological evaluation of the nodes was our reference.
DESIGN: This was a descriptive and prospective study. SETTINGS: Seventeen rectal specimens were examined in 2 series. The first series was conducted with 3 specimens from patients who were not given perioperative contrast; 3 had iodine-based contrast and 3 had gadolinium-based contrast. We concluded that iodine was the contrast agent of choice and therefore included 8 more patients in a second series, given iodine-based contrast, for further analysis. PATIENTS: Quantitative imaging data were collected from 197 individual lymph nodes from 17 specimens, from patients with rectal cancer. MAIN OUTCOME MEASURES: We measured accuracy of differentiating benign from malignant lymph nodes by investigating the following: 1) gadolinium, iodine, and water concentrations in lymph nodes; 2) dual-energy ratio; 3) dual-energy index; and 4) effective Z value.
RESULTS: Optimal discriminations between benign and malignant lymph nodes were obtained using the following cutoff values: 1) effective Z at 7.58 (sensitivity, 100%; specificity, 90%; and accuracy, 93%), 2) dual-energy ratio at 1.0 × 10 (sensitivity, 96%; specificity, 87%; and accuracy, 90%), 3) dual-energy index at 0.03 (sensitivity, 97%; specificity, 88%; and accuracy, 91%), and 4) iodine concentration at 2.58 μg/mL (sensitivity, 86%; specificity, 92%; and accuracy, 89%). LIMITATIONS: The investigation is conducted on isolated surgical specimens from rectal cancer operations.
CONCLUSIONS: Dual-energy CT can be performed on rectal specimens. The discrimination between benign and malignant nodes seems promising when using iodine as contrast.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27270516     DOI: 10.1097/DCR.0000000000000601

Source DB:  PubMed          Journal:  Dis Colon Rectum        ISSN: 0012-3706            Impact factor:   4.585


  2 in total

1.  A Dual-Energy CT Radiomics of the Regional Largest Short-Axis Lymph Node Can Improve the Prediction of Lymph Node Metastasis in Patients With Rectal Cancer.

Authors:  Dongqing Wang; Zijian Zhuang; Shuting Wu; Jixiang Chen; Xin Fan; Mengsi Liu; Haitao Zhu; Ming Wang; Jinmei Zou; Qun Zhou; Peng Zhou; Jing Xue; Xiangpan Meng; Shenghong Ju; Lirong Zhang
Journal:  Front Oncol       Date:  2022-06-07       Impact factor: 5.738

2.  Dual-energy CT quantitative parameters for evaluating Immunohistochemical biomarkers of invasive breast cancer.

Authors:  Xiaoxia Wang; Daihong Liu; Xiangfei Zeng; Shixi Jiang; Lan Li; Tao Yu; Jiuquan Zhang
Journal:  Cancer Imaging       Date:  2021-01-07       Impact factor: 3.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.