Hematocrit-Independent Quantitation of Stimulants in Dried Blood Spots: Pipet versus Microfluidic-Based Volumetric Sampling Coupled with Automated Flow-Through Desorption and Online Solid Phase Extraction-LC-MS/MS Bioanalysis.

Ruth Verplaetse1, Jack Henion1.   

Abstract

A workflow overcoming microsample collection issues and hematocrit (HCT)-related bias would facilitate more widespread use of dried blood spots (DBS). This report describes comparative results between the use of a pipet and a microfluidic-based sampling device for the creation of volumetric DBS. Both approaches were successfully coupled to HCT-independent, fully automated sample preparation and online liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis allowing detection of five stimulants in finger prick blood. Reproducible, selective, accurate, and precise responses meeting generally accepted regulated bioanalysis guidelines were observed over the range of 5-1000 ng/mL whole blood. The applied heated flow-through solvent desorption of the entire spot and online solid phase extraction (SPE) procedure were unaffected by the blood's HCT value within the tested range of 28.0-61.5% HCT. Enhanced stability for mephedrone on DBS compared to liquid whole blood was observed. Finger prick blood samples were collected using both volumetric sampling approaches over a time course of 25 h after intake of a single oral dose of phentermine. A pharmacokinetic curve for the incurred phentermine was successfully produced using the described validated method. These results suggest that either volumetric sample collection method may be amenable to field-use followed by fully automated, HCT-independent DBS-SPE-LC-MS/MS bioanalysis for the quantitation of these representative controlled substances. Analytical data from DBS prepared with a pipet and microfluidic-based sampling devices were comparable, but the latter is easier to operate, making this approach more suitable for sample collection by unskilled persons.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27270226     DOI: 10.1021/acs.analchem.6b01190

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Untargeted metabolomics profiling and hemoglobin normalization for archived newborn dried blood spots from a refrigerated biorepository.

Authors:  Miao Yu; Georgia Dolios; Vladimir Yong-Gonzalez; Olle Björkqvist; Elena Colicino; Jonas Halfvarson; Lauren Petrick
Journal:  J Pharm Biomed Anal       Date:  2020-08-23       Impact factor: 3.935

2.  Dried Volumetric Microsampling Approaches for the Therapeutic Drug Monitoring of Psychiatric Patients Undergoing Clozapine Treatment.

Authors:  Camilla Marasca; Roberto Mandrioli; Roccaldo Sardella; Tomaž Vovk; Andrea Armirotti; Andrea Cavalli; Alessandro Serretti; Michele Protti; Laura Mercolini
Journal:  Front Psychiatry       Date:  2022-06-01       Impact factor: 5.435

3.  Quantitative analysis of biofluid spots by coated blade spray mass spectrometry, a new approach to rapid screening.

Authors:  Germán Augusto Gómez-Ríos; Marcos Tascon; Nathaly Reyes-Garcés; Ezel Boyacı; Justen Poole; Janusz Pawliszyn
Journal:  Sci Rep       Date:  2017-11-23       Impact factor: 4.379