Literature DB >> 27269002

A Novel Semiautomated Fractional Limb Volume Tool for Rapid and Reproducible Fetal Soft Tissue Assessment.

Lauren M Mack1, Sung Yoon Kim2, Sungmin Lee3, Haleh Sangi-Haghpeykar4, Wesley Lee4.   

Abstract

The purpose of this study was to document the reproducibility and efficiency of a semiautomated image analysis tool that rapidly provides fetal fractional limb volume measurements. Fifty pregnant women underwent 3-dimensional sonographic examinations for fractional arm and thigh volumes at a mean menstrual age of 31.3 weeks. Manual and semiautomated fractional limb volume measurements were calculated, with the semiautomated measurements calculated by novel software (5D Limb Vol; Samsung Medison, Seoul, Korea). The software applies an image transformation method based on the major axis length, minor axis length, and limb center coordinates. A transformed image is used to perform a global optimization technique for determination of an optimal limb soft tissue boundary. Bland-Altman analysis defined bias with 95% limits of agreement (LOA) between methods, and timing differences between manual versus automated methods were compared by a paired t test. Bland-Altman analysis indicated an acceptable bias with 95% LOA between the manual and semiautomated methods: mean arm volume ± SD, 1.7% ± 4.6% (95% LOA, -7.3% to 10.7%); and mean thigh volume, 0.0% ± 3.8% (95% LOA, -7.5% to 7.5%). The computer-assisted software completed measurements about 5 times faster compared to manual tracings. In conclusion, semiautomated fractional limb volume measurements are significantly faster to calculate when compared to a manual procedure. These results are reproducible and are likely to reduce operator dependency. The addition of computer-assisted fractional limb volume to standard biometry may improve the precision of estimated fetal weight by adding a soft tissue component to the weight estimation process.

Entities:  

Keywords:  3-dimensional sonography; estimated fetal weight; fractional arm volume; fractional thigh volume; obstetric ultrasound

Mesh:

Year:  2016        PMID: 27269002     DOI: 10.7863/ultra.15.09086

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  2 in total

1.  Fetal weight estimation by automated three-dimensional limb volume model in late third trimester compared to two-dimensional model: a cross-sectional prospective observational study.

Authors:  Hua Meng; Yunshu Ouyang; Xining Wu; Zihan Niu; Zhonghui Xu; Yuxin Jiang; Yixiu Zhang
Journal:  BMC Pregnancy Childbirth       Date:  2021-05-08       Impact factor: 3.007

2.  Birth weight prediction by Lee formula based on fractional thigh volume in term pregnancies - is it helpful?

Authors:  Jakub Mlodawski; Daniel Wolder; Piotr Niziurski; Olga Adamczyk-Gruszka; Stanisław Głuszek; Wojciech Rokita
Journal:  Arch Med Sci       Date:  2020-01-31       Impact factor: 3.318

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.