Literature DB >> 27268518

An integrated platform for directly widely-targeted quantitative analysis of feces part I: Platform configuration and method validation.

Yuelin Song1, Qingqing Song2, Jun Li1, Jiao Zheng1, Chun Li1, Yuan Zhang3, Lingling Zhang2, Yong Jiang4, Pengfei Tu5.   

Abstract

Direct analysis is of great importance to understand the real chemical profile of a given sample, notably biological materials, because either chemical degradation or diverse errors and uncertainties might be resulted from sophisticated protocols. In comparison with biofluids, it is still challenging for direct analysis of solid biological samples using high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Herein, a new analytical platform was configured by online hyphenating pressurized liquid extraction (PLE), turbulent flow chromatography (TFC), and LC-MS/MS. A facile, but robust PLE module was constructed based on the phenomenon that noticeable back-pressure can be generated during rapid fluid passing through a narrow tube. TFC column that is advantageous at extracting low molecular analytes from rushing fluid was employed to link at the outlet of the PLE module to capture constituents-of-interest. An electronic 6-port/2-position valve was introduced between TFC column and LC-MS/MS to fragment each measurement into extraction and elution phases, whereas LC-MS/MS took the charge of analyte separation and monitoring. As a proof of concept, simultaneous determination of 24 endogenous substances including eighteen steroids, five eicosanoids, and one porphyrin in feces was carried out in this paper. Method validation assays demonstrated the analytical platform to be qualified for directly simultaneous measurement of diverse endogenous analytes in fecal matrices. Application of this integrated platform on homolog-focused profiling of feces is discussed in a companion paper.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Direct analysis; Feces; High performance liquid chromatography-tandem mass spectrometry; Online pressurized liquid extraction; Turbulent flow chromatography

Mesh:

Year:  2016        PMID: 27268518     DOI: 10.1016/j.chroma.2016.05.077

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Simultaneous Determination of Twenty-Five Compounds in Rat Plasma Using Ultra-High Performance Liquid Chromatography-Polarity Switching Tandem Mass Spectrometry and Its Application to a Pharmacokinetic Study.

Authors:  Na Zhang; Yueting Li; Jing Sun; Chun Li; Yuelin Song; Jun Li; Pengfei Tu; Yunfang Zhao
Journal:  Molecules       Date:  2017-10-30       Impact factor: 4.411

2.  [Chemome profiling of Pien-Tze-Huang by online pressurized liquid extraction-ultra-high performance liquid chromatography-ion trap-time-of-flight mass spectrometry].

Authors:  Wei Li; Zhenzhen Jiang; Han Li; Pengfei Tu; Qingqing Song; Juan Yu; Yuelin Song
Journal:  Se Pu       Date:  2021-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.